Optical influence of myopia control spectacles at the retinal level: Effect of local light modulation
Ophthalmic and Physiological Optics · 2025
DOI: 10.1111/opo.13515 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Hakan Kaymak und 5 weiteren Autor:innen. Beteiligte Einrichtung: Internationale Innovative Ophthalmochirurgie, Breyer Kaymak Klabe Augenchirurgie, Dusseldorf, Germany. Hauptthemen laut MEDLINE: Eyeglasses, Myopia, Retina, Light. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To investigate the influence of light modulation conferred by current designs of myopia control spectacles on retinal sensitivity.
Methods
Retinal sensitivity and scanning laser ophthalmoscopy (SLO) fundus images were obtained from nine healthy subjects using a Macular Integrity Assessment microperimeter with current myopia control spectacle lenses: MyoCare, Stellest, MiYOSMART and DOT. Respectively powered single vision lenses and a 0.8‐grade Bangerter occlusion foil (BF) served as comparative controls.
Results
Using the SLO image, one can visualise the areas of light modulation of the various myopia control lens designs at the level of the retina. Clear zone sizes differ between lens designs, with the DOT lens having the smallest area. Retinal sensitivity in areas of local light modulation was not reduced for the Stellest and MyoCare lenses, but declined with the MiYOSMART lens, suggesting a more prominent local light modulation. The DOT lenses produced a significant reduction in overall retinal sensitivity, although the reduction with the BF was greater. In all instances, retinal sensitivity remained well above the range considered normal for a healthy retina.
Conclusions
None of the lenses tested produced a clinically relevant reduction in retinal sensitivity and all scored significantly better than the lowest (that is, 0.8) grade BF. Given that current myopia control spectacles do not show consistent treatment effects as required to slow progression effectively over extended periods, there appears to be a subtle, yet crucial difference in spatial light modulation among these myopia control spectacle lenses. Seemingly similar lens designs cannot be assumed to have equivalent treatment effects; a thorough assessment of these nuances is essential to ensure accurate claims regarding their long‐term efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Internationale Innovative Ophthalmochirurgie, Breyer Kaymak Klabe Augenchirurgie, Dusseldorf, Germany.
- Gottfried O.H. Naumann-Institute of Epidemiology and Prevention of Myopia, Saarland University, Homburg, Germany.
- Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany.
- Department of Ophthalmology, Saarland University Medical Center, Homburg, Germany.
ORCID-Profile: Hakan Kaymak, Ann-Isabel Mattern, Birte Graff, Machteld Devenijn, Berthold Seitz, Hartmut Schwahn
Zitieren
APA
Kaymak, H., Mattern, A. I., Graff, B., Devenijn, M., Seitz, B., & Schwahn, H. (2025). Optical influence of myopia control spectacles at the retinal level: Effect of local light modulation. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13515
Vancouver
Kaymak H, Mattern AI, Graff B, Devenijn M, Seitz B, Schwahn H. Optical influence of myopia control spectacles at the retinal level: Effect of local light modulation. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13515
BibTeX
@article{Kaymak2025,
author = {Kaymak, Hakan and Mattern, Ann-Isabel and Graff, Birte and Devenijn, Machteld and Seitz, Berthold and Schwahn, Hartmut},
title = {Optical influence of myopia control spectacles at the retinal level: Effect of local light modulation},
journal = {Ophthalmic and Physiological Optics},
year = {2025},
doi = {10.1111/opo.13515}
}
EUVIMED