Retinal shadows produced by myopia control spectacles
Ophthalmic and Physiological Optics · 2024
DOI: 10.1111/opo.13228 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Martín de Tomas und 6 weiteren Autor:innen. Beteiligte Einrichtung: International Optics and Ophthalmology, Buenos Aires, Argentina. Hauptthemen laut MEDLINE: Myopia, Lens, Crystalline. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
Purpose
To analyse ocular coherence tomography (OCT) images of the retinal shadows caused by defocus and diffusion optics spectacles.
Methods
One eye was fitted successively with the Hoya Defocus Incorporated Multiple Segments (DIMS) spectacle lens, two variations of the +3.50 D peripheral add spectacle (DEFOCUS) and the low‐contrast dot lens (Diffusion Optics Multiple Segments, DOMS); each at a vertex distance of 12 mm. Simultaneously, a retinal image of the macular region with central fixation was obtained using infrared OCT. The corneal power and intraocular distances were determined using an optical biometer.
Results
The retinal images for the DIMS and DOMS lenses showed patterns of obvious retinal shadows in the periphery, while the central 10–11° remained clear. The DEFOCUS lens produced a darkened peripheral area. Dividing the size of the retinal pattern, measured with the calliper of the OCT software, by the actual size on the spectacle lens gave a magnification of −0.57 times. This is consistent with the incoming OCT beam being imaged to a position approximately 31 mm beyond the front of the eye. [Correction added on 26 October 2023 after first online publication: The preceding paragraph was corrected.]
Conclusion
With device‐specific correction, retinal OCT images can help visualise the regions affected by the defocus or lowered contrast induced by myopia control spectacles. This is of potential value for improving myopia therapies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- International Optics and Ophthalmology, Buenos Aires, Argentina.
- Department of Ophthalmology, Posadas Hospital Buenos Aires, Buenos Aires, Argentina.
- Opulens (Novar), Buenos Aires, Argentina.
- Reichert Technologies, Depew, New York, USA.
- Suárez Optical Laboratory, Buenos Aires, Argentina.
- Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
ORCID-Profile: David A Atchison, Rafael Iribarren
Zitieren
APA
de Tomas, M., Szeps, A., Martín, G., Suárez, J. M., Atchison, D. A., Rozema, J. J., & Iribarren, R. (2024). Retinal shadows produced by myopia control spectacles. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13228
Vancouver
de Tomas M, Szeps A, Martín G, Suárez JM, Atchison DA, Rozema JJ, et al. Retinal shadows produced by myopia control spectacles. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13228
BibTeX
@article{deTomas2024,
author = {de Tomas, Martín and Szeps, Abel and Martín, Gabriel and Suárez, Juan Manuel and Atchison, David A and Rozema, Jos J and Iribarren, Rafael},
title = {Retinal shadows produced by myopia control spectacles},
journal = {Ophthalmic and Physiological Optics},
year = {2024},
doi = {10.1111/opo.13228}
}
EUVIMED