EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non‐orthogonal spectacle correction for irregular astigmatism

Adela Hulpus, Ritchie Henry, Lynn White, Bernardo T Lopes, Vito Romano, Ahmed Abass iD

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.13405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Adela Hulpus und 5 weiteren Autor:innen. Beteiligte Einrichtung: St Pauls Eye Unit, Royal Liverpool University Hospital, Liverpool, UK. Hauptthemen laut MEDLINE: Astigmatism, Visual Acuity, Eyeglasses, Refraction, Ocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fight for Sight and the UK Keratoconus Self-Help and Support Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the potential improvement in visual acuity and subjective perception of image quality in patients with keratoconus using non‐orthogonal correction (NOC) cylinder trial lenses where the steep and flat power meridians are set at angles less or greater than 90°.

Methods

A set of NOC plano/cylindrical trial lenses, where the axes between the power meridians were set at a range of non‐orthogonal angles, were used to refract 18 participants with keratoconus in whom 23 eyes were used for testing. Corneal elevation data were processed by bespoke MATLAB code from Pentacam Scheimpflug tomographer scans. Each participant first underwent subjective refraction using standard orthogonal cylinder trial lenses, and the monocular best‐corrected visual acuity (BCVA, logMAR) was recorded for each eye. They then underwent a second subjective refraction using NOC cylinder trial lenses created for the study and completed a questionnaire to elicit their subjective appraisal of letter clarity and ghosting.

Results

Fourteen (61%) eyes demonstrated an increase in objective BCVA with the NOC versus the orthogonal correction; seven (30%) eyes showed no change and in two (9%) eyes, the BCVA was slightly worse. Further, 87% and 79% experienced an increase in letter clarity and a reduction in ghosting, respectively, independent of changes in BCVA. The majority of non‐orthogonal angles were in the range of 80°–85°, and it was possible to refine the cylinder and axis of the NOC further compared with the orthogonal correction. All but one of the participants said they would be interested in trying non‐orthogonal spectacles if the opportunity arose.

Conclusions

Correcting irregular astigmatism in keratoconic individuals with non‐orthogonal spectacle correction may provide benefit in terms of increased visual acuity, improvements in letter clarity and a reduction of ghosting effects. This type of correction has the potential to improve the overall quality of life for patients with keratoconus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismVisual AcuityEyeglassesRefraction, OcularCorneal TopographyKeratoconusHumansFemaleAdultMaleYoung Adult

Stichwörter der Autor:innen

astigmatismcorneanon‐orthogonal astigmatismoptical power

Autor:innen und Institutionen

  • St Pauls Eye Unit, Royal Liverpool University Hospital, Liverpool, UK.
  • Abergele Hospital, Betsi Cadwaladr University Health Board, Conwy, UK.
  • Department of Research and Development, LWVision, Leicestershire, UK.
  • Ophthalmology Eye Clinic, Alder Hey Children's NHS Foundation Trust, Liverpool, UK.
  • Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, Ophthalmology Clinic, University of Brescia, Brescia, Italy.
  • ASST Spedali Civili di Brescia, Brescia, Italy.

ORCID-Profile: Ahmed Abass

Förderung

  • Fight for Sight and the UK Keratoconus Self-Help and Support Association

Zitieren

APA

Hulpus, A., Henry, R., White, L., Lopes, B. T., Romano, V., & Abass, A. (2025). Non‐orthogonal spectacle correction for irregular astigmatism. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13405

Vancouver

Hulpus A, Henry R, White L, Lopes BT, Romano V, Abass A. Non‐orthogonal spectacle correction for irregular astigmatism. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13405

BibTeX
@article{Hulpus2025,
  author = {Hulpus, Adela and Henry, Ritchie and White, Lynn and Lopes, Bernardo T and Romano, Vito and Abass, Ahmed},
  title = {Non‐orthogonal spectacle correction for irregular astigmatism},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.13405}
}
Kostenlos starten →