EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Generalised models of the vertebrate eye

Jos J Rozema iD

Ophthalmic and Physiological Optics · 2024

DOI: 10.1111/opo.13376 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Jos J Rozema. Beteiligte Einrichtung: Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium. Hauptthemen laut MEDLINE: Models, Biological. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To present a set of closed‐form analytical equations to create a consistent eye model balance based on clinically measured input parameters in a single step. These models complement the existing iterative approaches in the literature.

Methods

Two different approaches are presented, both considering the cornea and lens as equivalent thin lenses. The first, called the Gaussian model, starts by defining the refractive error as the difference between the axial power (or dioptric distance) and the whole eye power, which can be expanded by filling in the formulas for each power. The resulting equation can be solved for either the refractive error, axial length, corneal power, lens power or the distance between the cornea and the lens as a function of the other four parameters. The second approach uses vergence calculations to provide alternative expressions, assuming that the refractive error is located at the corneal plane. Both models are explored for a biometric range typically found in adult human eyes.

Results

The Gaussian and vergence models each instantly balance the input data into a working eye model over the human physiological range and far beyond as demonstrated in various examples. The equations of the Gaussian model are more complicated, while the vergence model experiences more singularities, albeit in trivial or highly unlikely parameter combinations.

Conclusions

The proposed equations form a flexible and robust platform to create eye models from clinical data. Possible applications lie in creating animal eye models or providing a generic reference for real biometric data and the relationships between the ocular dimensions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, BiologicalHumansCorneaRefraction, OcularLens, CrystallineRefractive ErrorsAnimalsVertebratesNormal DistributionBiometry

Stichwörter der Autor:innen

ametropiaemmetropiaeye modelocular biometry

Autor:innen und Institutionen

  • Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium.
  • Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium.
  • Institute for Medical Informatics, Statistics, and Epidemiology (IMISE), Leipzig University, Leipzig, Germany.

ORCID-Profile: Jos J Rozema

Zitieren

APA

Rozema, J. J. (2024). Generalised models of the vertebrate eye. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13376

Vancouver

Rozema JJ. Generalised models of the vertebrate eye. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13376

BibTeX
@article{Rozema2024,
  author = {Rozema, Jos J},
  title = {Generalised models of the vertebrate eye},
  journal = {Ophthalmic and Physiological Optics},
  year = {2024},
  doi = {10.1111/opo.13376}
}
Kostenlos starten →