EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Refractive power profiles of commercially available soft multifocal contact lenses for myopia control

Rebecca M Dang iD, Klaus Ehrmann iD, Isabelle Jalbert iD, Alex Hui iD, Pauline Kang iD

Ophthalmic and Physiological Optics · 2024

DOI: 10.1111/opo.13345 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Rebecca M Dang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Myopia, Refraction, Ocular. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Lens power profiles can provide valuable insights on the imposed optical defocus and visual experience of contact lens wearers, especially in the context of myopia control. This study measured the refractive power profiles of multifocal soft contact lenses (MFCLs) currently used or that have the potential for use in myopia control using high spatial resolution aberrometry. The instrument's repeatability for determining MFCLs power profiles was also assessed.

Method

The power profiles of 10 MFCLs of various designs (centre‐distance, centre‐near and extended depth of focus) were measured using the Lambda‐X NIMO EVO , a phase shifting Schlieren‐based device. Power profiles were graphically expressed as measured power at each chord position and the maximum add power was calculated. The repeatability of the NIMO EVO was expressed as the within‐subject standard deviation at each chord position for a subset of five MFCLs.

Results

The measured distance powers differed from nominal powers for more than half of the MFCLs with a definable distance zone. There were variations in the chord position of the distance and near correction zones, rate of power transitions and calculated maximum add between the MFCLs which did not depend on lens design. For half of the MFCLs, the power profile shape was inconsistent between different nominal back vertex powers of the same design. The repeatability of the NIMO EVO was dependent on the lens design, with designs featuring faster rates of power change exhibiting worse repeatability.

Conclusions

Significant differences in MFCL power profiles were found which were not adequately represented in labelling. This is likely due to the small number of parameters used to define lens power characteristics. Eye health care practitioners should be aware of potential differences in power profiles between different MFCLs, which will impact the retinal defocus introduced during lens wear and the wearer's visual experience.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact Lenses, HydrophilicMyopiaRefraction, OcularHumansAdultReproducibility of ResultsEquipment DesignAberrometryMaleFemale

Stichwörter der Autor:innen

metrologymultifocal contact lensmyopia controlpower profiles

Autor:innen und Institutionen

  • School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia.
  • Nthalmic Pty Ltd, Botany, New South Wales, Australia.
  • Centre for Ocular Research and Education, University of Waterloo, Waterloo, Ontario, Canada.

ORCID-Profile: Rebecca M Dang, Klaus Ehrmann, Isabelle Jalbert, Alex Hui, Pauline Kang

Zitieren

APA

Dang, R. M., Ehrmann, K., Jalbert, I., Hui, A., & Kang, P. (2024). Refractive power profiles of commercially available soft multifocal contact lenses for myopia control. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13345

Vancouver

Dang RM, Ehrmann K, Jalbert I, Hui A, Kang P. Refractive power profiles of commercially available soft multifocal contact lenses for myopia control. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13345

BibTeX
@article{Dang2024,
  author = {Dang, Rebecca M and Ehrmann, Klaus and Jalbert, Isabelle and Hui, Alex and Kang, Pauline},
  title = {Refractive power profiles of commercially available soft multifocal contact lenses for myopia control},
  journal = {Ophthalmic and Physiological Optics},
  year = {2024},
  doi = {10.1111/opo.13345}
}
Kostenlos starten →