Assessment of large‐diameter and small‐diameter SoftK specialty contact lenses for early‐stage keratoconus
Ophthalmic and Physiological Optics · 2024
DOI: 10.1111/opo.13331 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Eyal Gal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel. Hauptthemen laut MEDLINE: Keratoconus, Visual Acuity, Contact Lenses, Hydrophilic, Cross-Over Studies. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Introduction
Soft contact lenses may be a good alternative for early‐stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc).
Methods
Patients with Amsler–Krumeich grades I or II KC were fitted with small‐diameter (14.2 or 14.8 mm) SoftK (SD‐SoftK, cc = 0.48 mm) and large‐diameter (17 mm) SoftK (LD‐SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli‐Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post‐hoc analysis.
Results
Forty eyes ( N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23–55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD‐SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD‐SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD‐SoftK lenses significantly improved 10VA compared with habitual and LD‐SoftK. SD‐SoftK also significantly improved CS compared with habitual, but not LD‐SoftK. LD‐SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 μ vs. 0.07 ± 0.13 μ) but not SD‐SoftK (0.04 ± 0.07 μ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD‐SoftK ( N = 3) compared with LD‐SoftK ( N = 8), and 75% of participants preferred SD‐SoftK lenses.
Conclusion
SD‐SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD‐SoftK lenses. SD‐SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD‐SoftK lenses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry and Vision Science, Hadassah Academic College, Jerusalem, Israel.
- Universitat Politècnica de Catalunya, University Vision Centre, Terrassa, Barcelona, Spain.
ORCID-Profile: Eyal Gal, Liat Gantz
Zitieren
APA
Gal, E., Gispets, J., Zyroff, M., Netanya, E., & Gantz, L. (2024). Assessment of large‐diameter and small‐diameter SoftK specialty contact lenses for early‐stage keratoconus. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13331
Vancouver
Gal E, Gispets J, Zyroff M, Netanya E, Gantz L. Assessment of large‐diameter and small‐diameter SoftK specialty contact lenses for early‐stage keratoconus. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13331
BibTeX
@article{Gal2024,
author = {Gal, Eyal and Gispets, Joan and Zyroff, Meira and Netanya, Efrat and Gantz, Liat},
title = {Assessment of large‐diameter and small‐diameter SoftK specialty contact lenses for early‐stage keratoconus},
journal = {Ophthalmic and Physiological Optics},
year = {2024},
doi = {10.1111/opo.13331}
}
EUVIMED