EUVIMEDSkopri EUVIMED
VergleichsstudieOpen access · CC BY-NC-ND 4.0

Predictability of In‐Office Clear Aligner at Final Canine Retraction: A Comparison of Interproximal Contact Tightness and Canine Distalization Between Virtual and Actual Outcomes in Premolar Extraction Cases

Sawitt Eurutairat iD, Thanchanok Prokati iD, Sakda Wonghinkong iD, Somchai Manopatanakul iD, Peerapong Santiwong iD, Nita Viwattanatipa iD

Orthodontics & Craniofacial Research · 2025

DOI: 10.1111/ocr.70074 ↗

At a glance

Vergleichsstudie in Orthodontics & Craniofacial Research, 2025. Written by Sawitt Eurutairat and 5 co-authors. Institution: Faculty of Dentistry, Mahidol University, Bangkok, Thailand. Major MEDLINE topics: Bicuspid, Cuspid, Tooth Extraction, Tooth Movement Techniques. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Faculty of Dentistry, Mahidol University and Faculty of Graduate Studies, Mahidol University.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Objective

This retrospective study aimed to evaluate interproximal contact tightness (ICT) at completion of maxillary canine retraction in first premolar extraction cases treated with In‐office Clear Aligner (IOCA). Materials and Methods The study sample comprised 18 subjects who underwent maxillary first premolar extractions. All cases were treated using a multi‐stage intraoral scanning protocol, followed by digital laboratory set‐up for the fabrication of IOCA. Recorded data of both virtual and actual stereolithography models at completion of canine retraction were collected. The ICT between the maxillary canine and second premolar was evaluated using (1) virtual residual extraction space (VRS) and (2) actual residual extraction space (ARS). Using superimposed models, canine distalization was assessed through (1) virtual canine distalization (VCD) and (2) actual canine distalization (ACD). All measurements were performed using GOM Inspect Suite. Statistical analysis involved the Wilcoxon signed‐rank test and paired t ‐test.

Results

Interproximal contact tightness of the actual group (median 0.46 mm; 95% CI: 0.41–0.58 mm) demonstrated statistically significant larger residual space than the virtual group (median 0.11 mm; 95% CI: 0.10–0.21 mm). The median difference between ARS and VRS was 0.28 mm (95% CI: 0.26–0.42 mm). The mean VCD was significantly greater (7.41 ± 0.89 mm) than the ACD (7.18 ± 0.97 mm).

Conclusion

The actual interproximal contacts were not completely closed, in contrast to the complete contact predicted by the 3D virtual setup. To prevent this remaining gap, it is recommended to perform fake interproximal stripping or tooth collision during the virtual planning stage.

Subjects

MeSH terms (MEDLINE)

BicuspidCuspidTooth ExtractionTooth Movement TechniquesOrthodontic Appliance DesignHumansMaleFemaleRetrospective StudiesMaxillaAdolescentYoung AdultTreatment OutcomeModels, DentalAdult

Author keywords

accuracycanine distalizationinterproximal contact tightnessin‐office clear alignerpremolar extraction

Authors and institutions

  • Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
  • Wanon Niwat Hospital, Sakon Nakhon, Thailand.
  • Private Practice, Bangkok, Thailand.
  • Department of Orthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.

ORCID profiles: Sawitt Eurutairat, Thanchanok Prokati, Sakda Wonghinkong, Somchai Manopatanakul, Peerapong Santiwong, Nita Viwattanatipa

Funding

  • Faculty of Dentistry, Mahidol University and Faculty of Graduate Studies, Mahidol University

Cite

APA

Eurutairat, S., Prokati, T., Wonghinkong, S., Manopatanakul, S., Santiwong, P., & Viwattanatipa, N. (2025). Predictability of In‐Office Clear Aligner at Final Canine Retraction: A Comparison of Interproximal Contact Tightness and Canine Distalization Between Virtual and Actual Outcomes in Premolar Extraction Cases. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.70074

Vancouver

Eurutairat S, Prokati T, Wonghinkong S, Manopatanakul S, Santiwong P, Viwattanatipa N. Predictability of In‐Office Clear Aligner at Final Canine Retraction: A Comparison of Interproximal Contact Tightness and Canine Distalization Between Virtual and Actual Outcomes in Premolar Extraction Cases. Orthodontics & Craniofacial Research. 2025. doi:10.1111/ocr.70074

BibTeX
@article{Eurutairat2025,
  author = {Eurutairat, Sawitt and Prokati, Thanchanok and Wonghinkong, Sakda and Manopatanakul, Somchai and Santiwong, Peerapong and Viwattanatipa, Nita},
  title = {Predictability of In‐Office Clear Aligner at Final Canine Retraction: A Comparison of Interproximal Contact Tightness and Canine Distalization Between Virtual and Actual Outcomes in Premolar Extraction Cases},
  journal = {Orthodontics & Craniofacial Research},
  year = {2025},
  doi = {10.1111/ocr.70074}
}
Start for free →