EUVIMEDScopri EUVIMED
Crossref

Biomechanical Effect of Unexpected Minor Aligner Circumference Changes on Lower Incisors During Intrusion: A Finite Element Analysis

Xiaoni Duan iD, Yiru Jiang, Jue Wang, Li Xu, Yanmei Huang, Lu Zhang, Wen Li iD, Xiaoxia Feng

Orthodontics & Craniofacial Research · 2025

DOI: 10.1111/ocr.70012 ↗

At a glance

Journal article in Orthodontics & Craniofacial Research, 2025. Written by Xiaoni Duan and 7 co-authors. Institution: Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, …. Major MEDLINE topics: Incisor, Tooth Movement Techniques, Orthodontic Appliance Design, Orthodontic Appliances, Removable. 21 references. Funded by: The Research and Development Project of Stomatology Hospital Zhejiang University School of Medicine, Zhejiang Provincial Natural Science Foundation of China.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Objective

Unplanned changes in aligner circumference may occur during anterior teeth intrusion with clear aligner treatment (CAT), potentially affecting root movement, an important yet often overlooked factor. This study investigated the biomechanical effects of minor aligner circumference changes on lower incisors during intrusion. Materials and Methods Nine finite element analysis models of CAT were created based on the original model. These models were divided into the following groups: the 2 groups of incisors intrusion (0.25 and 0.5 mm), 3 groups of 0.25 mm intrusion combined with aligner circumference changes (−0.1, −0.2 and + 0.1 mm), and 4 groups of 0.25 mm intrusion combined with labial crown torque (0.5°, 1°, 1.5° and 2°).

Results

Compared to the control group (0.25 mm intrusion), the experimental group (0.5 mm intrusion) showed that lower incisors exhibited greater vertical intrusion (0.016 mm vs. 0.012 mm), more lingual crown movement (0.10 mm vs. 0.04 mm), and increased labial root movement (0.021 mm vs. 0.006 mm) sagittally. The 0.25 mm intrusion combined with a −0.1 mm aligner circumference increased labial root movement of lower incisors. As the aligner circumference shortened, this effect became more pronounced. Conversely, the group with a +0.1 mm aligner circumference reduced labial root movement. With additional labial crown torque applied to the lower incisors, the roots shifted from labial to lingual. The central incisor achieved pure intrusion at a labial crown torque of 1.06° per 0.25 mm intrusion.

Conclusions

Minor changes in the aligner circumference might significantly induce sagittal root movement of lower incisors during intrusion. Orthodontists should carefully monitor unplanned variations in aligner circumference during incisor intrusion to minimise unintended root movement.

Subjects

MeSH terms (MEDLINE)

IncisorTooth Movement TechniquesOrthodontic Appliance DesignOrthodontic Appliances, RemovableFinite Element AnalysisBiomechanical PhenomenaHumansTorqueTooth RootDental Stress AnalysisMandible

Author keywords

aligner circumferenceclear aligner treatmentfinite element analysisintrusion

Authors and institutions

  • Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cance…
  • Division of Pediatric Dentistry and Orthodontics, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.

ORCID profiles: Xiaoni Duan, Wen Li

Funding

  • The Research and Development Project of Stomatology Hospital Zhejiang University School of Medicine
  • Zhejiang Provincial Natural Science Foundation of China

Cite

APA

Duan, X., Jiang, Y., Wang, J., Xu, L., Huang, Y., Zhang, L., Li, W., & Feng, X. (2025). Biomechanical Effect of Unexpected Minor Aligner Circumference Changes on Lower Incisors During Intrusion: A Finite Element Analysis. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.70012

Vancouver

Duan X, Jiang Y, Wang J, Xu L, Huang Y, Zhang L, et al. Biomechanical Effect of Unexpected Minor Aligner Circumference Changes on Lower Incisors During Intrusion: A Finite Element Analysis. Orthodontics & Craniofacial Research. 2025. doi:10.1111/ocr.70012

BibTeX
@article{Duan2025,
  author = {Duan, Xiaoni and Jiang, Yiru and Wang, Jue and Xu, Li and Huang, Yanmei and Zhang, Lu and Li, Wen and Feng, Xiaoxia},
  title = {Biomechanical Effect of Unexpected Minor Aligner Circumference Changes on Lower Incisors During Intrusion: A Finite Element Analysis},
  journal = {Orthodontics & Craniofacial Research},
  year = {2025},
  doi = {10.1111/ocr.70012}
}
Start for free →