In Vitro Comparison of Direct Attachment Shape and Size on the Orthodontic Forces and Moments Generated by Thermoplastic Aligners During Expansion
Orthodontics & Craniofacial Research · 2025
DOI: 10.1111/ocr.12865 ↗At a glance
Vergleichsstudie in Orthodontics & Craniofacial Research, 2025. Written by Megann Lear and 8 co-authors. Institution: Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, Indianapolis, Indiana, USA. Major MEDLINE topics: Orthodontic Appliance Design, Tooth Movement Techniques. Cited 6 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Objective
To evaluate the effects of varying direct attachment shape and size on the forces and moments generated by thermoplastic aligners during simulated expansion. Materials and Methods An in vitro orthodontic force tester (OFT) was used to measure the forces and moments from a typodont where the buccal teeth were translated lingually 0.2 mm to simulate expansion. Hemi‐ellipsoid and rectangular attachments with either 0.5 or 1.0 mm thickness were added on upper right first premolar (UR4), second premolar (UR5) and first molar (UR6). Analysis of variance (ANOVA) was used to determine two‐way interactions among the factors on the outcomes.
Results
The interactions between group and tooth were significant for all outcomes ( p < 0.001). The greatest buccal forces (Fy) were observed with 1 mm rectangular attachment on the UR4 (0.78 ± 0.29 N), with 1 mm hemi‐ellipsoid attachment on UR5 (0.28 ± 0.21 N) and with 0.5 mm rectangular attachment on UR6 (1.71 ± 0.18 N). The greatest buccolingual moments (Mx) were obtained with 1 mm rectangular attachment on UR4 (5.61 ± 1.43 Nmm), without any attachments on UR5 (3.33 ± 1.73 Nmm) and with 1 mm hemi‐ellipsoid attachment on UR6 (4.18 ± 4.31).
Conclusion
Direct attachment shape and size had a significant effect on the orthodontic forces and moments generated by thermoplastic aligners during simulated expansion. Although loads varied significantly by tooth morphology and its location in the arch, best forces and moments for expansion were obtained with 1 mm rectangular attachments on UR4s, 1 mm hemi‐ellipsoid attachments on UR5s and 0.5 mm rectangular attachments on UR6s.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, Indianapolis, Indiana, USA.
- Purdue University School of Mechanical Engineering, Indianapolis, Indiana, USA.
- Indiana University School of Dentistry, Indianapolis, Indiana, USA.
- Department of Biostatistics, Indiana University School of Medicine, Indianapolis, Indiana, USA.
ORCID profiles: Richard Scott Conley, Hakan Turkkahraman
Cite
APA
Lear, M., Akbari, A., Robertson, O., Magura, J., Bojrab, A., Eckert, G., Chen, J., Conley, R. S., & Turkkahraman, H. (2025). In Vitro Comparison of Direct Attachment Shape and Size on the Orthodontic Forces and Moments Generated by Thermoplastic Aligners During Expansion. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12865
Vancouver
Lear M, Akbari A, Robertson O, Magura J, Bojrab A, Eckert G, et al. In Vitro Comparison of Direct Attachment Shape and Size on the Orthodontic Forces and Moments Generated by Thermoplastic Aligners During Expansion. Orthodontics & Craniofacial Research. 2025. doi:10.1111/ocr.12865
BibTeX
@article{Lear2025,
author = {Lear, Megann and Akbari, Amin and Robertson, Olivia and Magura, Janine and Bojrab, Alexandra and Eckert, George and Chen, Jie and Conley, Richard Scott and Turkkahraman, Hakan},
title = {In Vitro Comparison of Direct Attachment Shape and Size on the Orthodontic Forces and Moments Generated by Thermoplastic Aligners During Expansion},
journal = {Orthodontics & Craniofacial Research},
year = {2025},
doi = {10.1111/ocr.12865}
}
EUVIMED