EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Accuracy of measurements on CBCT‐generated digital models using different exposure parameters (in vitro study)

Noura Ibrahim iD, Hassan Mohamed Abouelkheir, Noha Mohamed Elkersh iD

Orthodontics & Craniofacial Research · 2025

DOI: 10.1111/ocr.12854 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Orthodontics & Craniofacial Research, 2025. Verfasst von Noura Ibrahim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Models, Dental. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Dental imaging comprises a wide range of techniques and modalities, each with different diagnostic features influenced by numerous parameters, all of which contribute to the precision and effectiveness of dental evaluations and treatments. This study examined the dimensional reproducibility of arch measurements from CBCT scans with different voxel sizes and exposure parameters compared to a reference model from Extra‐oral scanners (EOS) and how these parameters affected digital matching and diagnostic image quality.

Methods

A diagnostic observational study of arch dimensions, including inter‐canine, inter‐premolar, intermolar, arch width and arch length, was conducted on digital models (DMs) created from 65 CBCT scans of a full dentate epoxy maxillary model. The measurements obtained from EOS scans served as the control for the study. Normality was tested with the Shapiro–Wilk test, comparisons used the Kruskal–Wallis test with Bonferroni‐adjusted pairwise comparisons for significant results, and data were analysed using IBM SPSS (Version 26.0), with significance set at p < .05.

Results

Significant deviations were revealed among study groups, with group I (smallest voxel size) consistently displaying the lowest values, mean (SD) deviation was reported as 0.01 (0.006) and group IV (lowest kV value) exhibiting the highest deviations, mean (SD) deviation of 0.16 (0.17).

Conclusion

Combining a small voxel size (0.12 mm) with high milliampere (8 mA) and kilovoltage (90 kV) settings in CBCT ensured detailed anatomical visualization and accurate linear measurements, crucial for precise dental assessments, and emphasizing the necessity for strict control over CBCT parameters in dental applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyModels, DentalHumansDental ArchImaging, Three-DimensionalIn Vitro TechniquesMaxillaReproducibility of Results

Stichwörter der Autor:innen

cone‐beam computed tomographydentaldigitalimagingradiographythree‐dimensional

Autor:innen und Institutionen

  • Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
  • College of Dentistry, Arab Academy for Science, Technology and Maritime Transport, Alamein, Egypt.
  • London University, London, UK.
  • Dundee University, Dundee, UK.

ORCID-Profile: Noura Ibrahim, Noha Mohamed Elkersh

Zitieren

APA

Ibrahim, N., Abouelkheir, H. M., & Elkersh, N. M. (2025). Accuracy of measurements on CBCT‐generated digital models using different exposure parameters (in vitro study). Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12854

Vancouver

Ibrahim N, Abouelkheir HM, Elkersh NM. Accuracy of measurements on CBCT‐generated digital models using different exposure parameters (in vitro study). Orthodontics & Craniofacial Research. 2025. doi:10.1111/ocr.12854

BibTeX
@article{Ibrahim2025,
  author = {Ibrahim, Noura and Abouelkheir, Hassan Mohamed and Elkersh, Noha Mohamed},
  title = {Accuracy of measurements on CBCT‐generated digital models using different exposure parameters (in vitro study)},
  journal = {Orthodontics & Craniofacial Research},
  year = {2025},
  doi = {10.1111/ocr.12854}
}
Kostenlos starten →