EUVIMEDEUVIMED entdecken
Crossref

Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study

Elissa Kondakji, Ghida Lawand, Wassim Yaacoub, Hani Tohme

The Journal of Prosthetic Dentistry · 2024

DOI: 10.1016/j.prosdent.2024.05.019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Elissa Kondakji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon. Electr…. Hauptthemen laut MEDLINE: Dental Implants, Computer-Aided Design, Dental Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The effect of different surface locking patterns on the trueness of a digital implant scan of a completely edentulous arch remains uncertain. PURPOSE: The purpose of this in vitro study was to evaluate whether locking surfaces with different patterns affected the trueness of complete arch implant digital scans. MATERIAL AND METHODS: An edentulous maxillary cast with 4 implants (2 anterior implants parallel and 2 posterior implants tilted at 17 degrees) was fabricated. Four implant-level scan bodies were fixed onto the implants, and the cast was scanned with a desktop scanner to create the reference file. Four groups (L0, L1, L2, and L3) were formed, each with a distinct locking surface configuration, and all scans were made using the same intraoral scanner. L0 kept all 4 implant-level scan bodies during scanning. L1 involved removing the right first premolar (RPM) scan body, scanning the other 3 implant scan bodies, then reattaching the RPM's scan body, and continuing scanning. In L2, the RPM and right lateral incisor (RIC) scan bodies were removed, followed by scanning the left implants to create a locking surface, and scanning the right implants. In L3, only the left posterior molar's (LPM) scan body was retained and scanned; then a locking surface was generated, and then the remaining implants were scanned. A metrology software program (Geomagic Control X) was used for comparison. Statistical analyses were performed using the Kruskal-Wallis, the 1-way ANOVA, the Welch ANOVA, the Friedman test, the repeated-measures ANOVA, the Bonferroni post hoc test, and the Games-Howell post hoc test (α=.05). RESULTS: Significant 3D surface deviations were observed in the coronal bevel (CB) region and in the entire scan bodies when assessing trueness in the L0, L1, L2, and L3 groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsComputer-Aided DesignDental Prosthesis DesignHumansIn Vitro TechniquesSurface PropertiesImaging, Three-DimensionalMaxillaModels, DentalJaw, EdentulousDental Arch

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Resident, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon. Electronic address: elissakondakji@hotmail.com.
  • Clinical Instructor, Department of Removable and Fixed Prosthodontics, Beirut Arab University, Beirut, Lebanon.
  • Resident, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon.
  • Founder and Head, Department of Digital Dentistry, Artificial Intelligence, and Evolving Technologies, Saint Joseph University of Beirut, Beirut, Lebanon; and Postgraduate Program Director, Department of Removable Prost…

Zitieren

APA

Kondakji, E., Lawand, G., Yaacoub, W., & Tohme, H. (2024). Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.05.019

Vancouver

Kondakji E, Lawand G, Yaacoub W, Tohme H. Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.05.019

BibTeX
@article{Kondakji2024,
  author = {Kondakji, Elissa and Lawand, Ghida and Yaacoub, Wassim and Tohme, Hani},
  title = {Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  doi = {10.1016/j.prosdent.2024.05.019}
}
Kostenlos starten →