Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations
Orthodontics & Craniofacial Research · 2024-12 · 27 (6) · 996-1003
DOI: 10.1111/ocr.12846 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthodontics & Craniofacial Research, online erschienen am 19.08.2024. Verfasst von Gianluigi Fiorillo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy. Hauptthemen laut MEDLINE: Tooth Movement Techniques. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To evaluate the accuracy of dental rotational movements using clear aligners with different attachment configurations. Materials and Methods This retrospective study analysed 212 teeth from 89 patients undergoing Invisalign treatment. Digital models were analysed after the virtual treatment plan (ST1) and after the first treatment phase (ET1) to evaluate the effective clinical rotational movement. The rotational movements of incisors, canines, and bicuspids were measured using data from the Clincheck Movements Table. ST1 and ET1 were compared to determine the actual rotational movement achieved (ST1‐ET1). The presence or absence of attachments (rectangular or optimized) on teeth was analysed. The accuracy of rotational movements among attachment types was compared using the Kruskal‐Wallis test. Multiple linear regressions were conducted with accuracy as the dependent variable and tooth type, gender, and age as predictors.
Results
Optimized attachments had the highest median accuracy (70%), followed by rectangular (65%), and without attachment (63%), with no significant differences ( p = .5). There were no significant differences across age groups, genders, or tooth types. Baseline accuracy was 68.62% (95% CI: 56.03–81.20, p < .001). Age was a significant predictor (estimate = −0.30, 95% CI: −0.58 – −0.03, p = .032), indicating decreased accuracy with increasing age. The model's R 2 was 0.046, with an adjusted R 2 of 0.003, indicating minimal variance explained.
Conclusion
The addition of attachment configurations to clear aligners improves rotational accuracy, but not significantly. Further advancements in these configurations are needed to enhance the performance of the aligners.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dental School, San Raffaele Vita-Salute University of Milan, Milan, Italy.
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
- Department of Orthodontics, Saidu College of Dentistry, Swat, Pakistan.
- Department of Translational Medicine and for Romagna, University of Ferrara, Ferrara, Italy.
ORCID-Profile: Alessandra Campobasso, Giovanni Battista
Zitieren
APA
Fiorillo, G., Campobasso, A., Croce, S., Hussain, U., Battista, G., Lo Muzio, E., Mandelli, G., Ambrosi, A., & Gastaldi, G. (2024). Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations. Orthodontics & Craniofacial Research, 27(6), 996-1003. https://doi.org/10.1111/ocr.12846
Vancouver
Fiorillo G, Campobasso A, Croce S, Hussain U, Battista G, Lo Muzio E, et al. Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations. Orthodontics & Craniofacial Research. 2024;27(6):996-1003. doi:10.1111/ocr.12846
BibTeX
@article{Fiorillo2024,
author = {Fiorillo, Gianluigi and Campobasso, Alessandra and Croce, Silvia and Hussain, Umar and Battista, Giovanni and Lo Muzio, Eleonora and Mandelli, Gualtiero and Ambrosi, Alessandro and Gastaldi, Giorgio},
title = {Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations},
journal = {Orthodontics & Craniofacial Research},
year = {2024},
volume = {27},
number = {6},
pages = {996--1003},
doi = {10.1111/ocr.12846}
}
EUVIMED