EUVIMEDDescoperă EUVIMED
Crossref

Biomechanical effects of clear aligner with different shape design at extraction space area during anterior teeth retraction

Bochun Mao, Yajing Tian, Yujia Xiao, Jiayi Liu, Dawei Liu, Jing Li, Yanheng Zhou iD

Orthodontics & Craniofacial Research · 2024-10 · 27 (5) · 740-749

DOI: 10.1111/ocr.12795 ↗

At a glance

Journal article in Orthodontics & Craniofacial Research, published online on 2024-04-23. Written by Bochun Mao and 6 co-authors. Institution: Department of Orthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Cente…. Major MEDLINE topics: Finite Element Analysis, Periodontal Ligament. Cited 15 times so far (Crossref); 21 references. Funded by: New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology, Research Foundation of Peking University School and Hospital of Stomatology, National Natural Science Foundation of China.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Objective

This study aimed to investigate the biomechanical effects of clear aligner (CA) with different shape designs at extraction space (CAES) area during space closing. Materials and Methods A finite‐element method (FEM) model of mandibular dentition, periodontal ligaments, attachments, and corresponding CA was established. The connecting rod design of CAES was modelled for the control group. Eight test groups with different heights of CAES from −4 mm to +4 mm were designed. Tooth displacement tendencies were calculated. The maximum principal stress in PDLs, teeth, and CAs was analysed. Both global coordinate system and local coordinate system were also used to evaluate individual tooth movements.

Results

Across all groups, stresses concentrated on the lingual outer surface of CAESs. For the lowered CAES groups, both the stress value and the stress distribution area at CAESs were increased. The lowered CAES groups showed reduced movement in anterior teeth and less tipping tendency of the canines.

Conclusion

The shape of CAES has a biomechanical impact on anterior teeth movement and should be considered in aligner design. The results suggest that increasing the height of CAES can enhance anterior teeth retraction, while lowered CAES may facilitate controlled root movement. Changes in the shape of CAES represent a potential direction for biomechanical improvement of clear aligner in extraction cases and are worth exploring.

Subjects

MeSH terms (MEDLINE)

Finite Element AnalysisPeriodontal LigamentHumansBiomechanical PhenomenaOrthodontic Appliance DesignTooth ExtractionTooth Movement TechniquesOrthodontic Space ClosureIncisorMandibleDental Stress AnalysisOrthodontic Appliances, RemovableStress, Mechanical

Author keywords

clear alignerextraction treatmentfinite element analysispontic

Authors and institutions

  • Department of Orthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Bio…
  • Center of Stomatology, China-Japan Friendship Hospital, Beijing, China.

ORCID profiles: Yanheng Zhou

Funding

  • New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology
  • Research Foundation of Peking University School and Hospital of Stomatology
  • National Natural Science Foundation of China
  • Scientific Research Project of Clear Aligner of Peking University School and Hospital of Stomatology
  • Beijing Municipal Natural Science Foundation

Cite

APA

Mao, B., Tian, Y., Xiao, Y., Liu, J., Liu, D., Li, J., & Zhou, Y. (2024). Biomechanical effects of clear aligner with different shape design at extraction space area during anterior teeth retraction. Orthodontics & Craniofacial Research, 27(5), 740-749. https://doi.org/10.1111/ocr.12795

Vancouver

Mao B, Tian Y, Xiao Y, Liu J, Liu D, Li J, et al. Biomechanical effects of clear aligner with different shape design at extraction space area during anterior teeth retraction. Orthodontics & Craniofacial Research. 2024;27(5):740-749. doi:10.1111/ocr.12795

BibTeX
@article{Mao2024,
  author = {Mao, Bochun and Tian, Yajing and Xiao, Yujia and Liu, Jiayi and Liu, Dawei and Li, Jing and Zhou, Yanheng},
  title = {Biomechanical effects of clear aligner with different shape design at extraction space area during anterior teeth retraction},
  journal = {Orthodontics & Craniofacial Research},
  year = {2024},
  volume = {27},
  number = {5},
  pages = {740--749},
  doi = {10.1111/ocr.12795}
}