EUVIMEDScopri EUVIMED
Open access · CC BY-NC-ND 4.0

The in vitro biomechanics of anterior arch expansion using fixed lingual appliances with coil springs or archwire stops

Lindsay Robertson, Brandon Owen, Gieson Heo, Jason P Carey, Paul W Major, Dan L Romanyk

Orthodontics & Craniofacial Research · 2023

DOI: 10.1111/ocr.12640 ↗

At a glance

Journal article in Orthodontics & Craniofacial Research, 2023. Written by Lindsay Robertson and 5 co-authors. Institution: School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. Major MEDLINE topics: Malocclusion, Orthodontic Brackets. 17 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: McIntyre Fund, School of Dentistry University of Alberta.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Introduction

The presented study investigates differences in the biomechanics of straight and mushroom fixed lingual appliances when implementing coil springs and stops for anterior arch expansion. Materials and Methods An in vitro orthodontic simulator was used to measure three‐dimensional forces and moments on each tooth of a simulated maxillary arch. Mushroom and straight archwire forms of 0.016″ NiTi round archwire were considered, using 0.010″ × 0.030″ NiTi open coils and 0.016″‐0.018″ archwire stops ( n = 44 per group). Teeth in the anterior dental arch were moved from a neutral to crowded position to replicate anterior crowding of central and lateral incisors. Forces and moments of interest for lateral incisors and first premolars were compared using repeated measures mixed multivariate analysis of variance ( α = 0.05).

Results

Three comparisons between straight versus mushroom archwires and two comparisons of coil springs vs. stops were not statistically significant. Overall, it was found that the use of a straight lingual archwire produced larger differences in forces and moments between using stops and coil springs than when using a mushroom archwire. Using stops produced larger forces and moments for both types of archwires as compared to using coil springs. The largest expansion forces were produced using straight archwires with stops, exceeding 3.0 N of force. Straight archwires with coil springs produced the lowest expansion forces on lateral incisors, just exceeding 1.5 N.

Conclusions

The findings of this study have elucidated significant differences in the biomechanics of transverse arch expansion using straight or mushroom fixed lingual appliances with coil springs or stops.

Subjects

MeSH terms (MEDLINE)

MalocclusionOrthodontic BracketsHumansBiomechanical PhenomenaOrthodontic Appliance DesignOrthodontic WiresOrthodontic Appliances, FixedTitaniumTooth Movement Techniques

Author keywords

archwire expansionfixed lingual applianceorthodontic biomechanicsorthodontic simulator

Substances

Titanium

Authors and institutions

  • School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
  • Private Practice, Fort Collins, Colorado, USA.
  • Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada.

Funding

  • McIntyre Fund, School of Dentistry University of Alberta

Cite

APA

Robertson, L., Owen, B., Heo, G., Carey, J. P., Major, P. W., & Romanyk, D. L. (2023). The in vitro biomechanics of anterior arch expansion using fixed lingual appliances with coil springs or archwire stops. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12640

Vancouver

Robertson L, Owen B, Heo G, Carey JP, Major PW, Romanyk DL. The in vitro biomechanics of anterior arch expansion using fixed lingual appliances with coil springs or archwire stops. Orthodontics & Craniofacial Research. 2023. doi:10.1111/ocr.12640

BibTeX
@article{Robertson2023,
  author = {Robertson, Lindsay and Owen, Brandon and Heo, Gieson and Carey, Jason P and Major, Paul W and Romanyk, Dan L},
  title = {The in vitro biomechanics of anterior arch expansion using fixed lingual appliances with coil springs or archwire stops},
  journal = {Orthodontics & Craniofacial Research},
  year = {2023},
  doi = {10.1111/ocr.12640}
}
Start for free →