EUVIMEDSkopri EUVIMED
Crossref

Evaluation of the accuracy of fully automatic cephalometric analysis software with artificial intelligence algorithm

Gökhan Serhat Duran iD, Şule Gökmen, Kübra Gülnur Topsakal, Serkan Görgülü

Orthodontics & Craniofacial Research · 2023-08 · 26 (3) · 481-490

DOI: 10.1111/ocr.12633 ↗

At a glance

Journal article in Orthodontics & Craniofacial Research, published online on 2023-01-24. Written by Gökhan Serhat Duran and 3 co-authors. Institution: Department of Orthodontics, Gulhane Faculty of Dental Medicine, University of Health Sciences, Ankara, Turkey. Major MEDLINE topics: Artificial Intelligence, Algorithms. Cited 38 times so far (Crossref); 27 references.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Objective

The aim of this study is to evaluate whether fully automatic cephalometric analysis software with artificial intelligence algorithms is as accurate as non‐automated cephalometric analysis software for clinical diagnosis and research. Materials and Methods This is a retrospective archive study using lateral cephalometric radiographs taken from individuals aged 12‐20 years. Cephalometric measurement data were obtained from these lateral cephalometric radiographs by manual landmark marking with non‐automated computer software (Dolphin 11.8). Again, the same radiographs were made using fully automatic digital cephalometric analysis software OrthoDx™ (AI‐Powered Orthodontic Imaging System, Phimentum) and WebCeph (Assemblecircle, Seoul, Korea) with artificial intelligence algorithm, without manual intervention of the researcher and fully automatic markings and measurements were made by the software.

Results

According to the consistency test, a statistically significant good level of consistency was found between Dolphin and OrthoDx™ measurements and Dolphin and WebCeph measurements in angular measurements (ICC > 0.75, P < .01, ICC > 0.75, P < 0, respectively. 01). A weak level of consistency was found in linear measurement and soft tissue parameters in both software (ICC < 0.50, P < .05, ICC < 0.50, P < .05), and the difference between measurements was statistically found to be different from “0.” Conclusion The results obtained from fully automatic cephalometric analysis software with artificial intelligence algorithms are similar to the results of non‐automated cephalometric analysis software, although there are differences in some parameters. To minimize the margin of error in artificial intelligence‐based fully automatic cephalometric software, the manual intervention of the observer is needed.

Subjects

MeSH terms (MEDLINE)

Artificial IntelligenceAlgorithmsRetrospective StudiesSoftwareRadiographyCephalometryReproducibility of Results

Author keywords

artificial intelligenceautomatic landmark detectioncephalometric analysis

Authors and institutions

  • Department of Orthodontics, Gulhane Faculty of Dental Medicine, University of Health Sciences, Ankara, Turkey.
  • Private practice, Ankara, Turkey.

ORCID profiles: Gökhan Serhat Duran

Cite

APA

Duran, G. S., Gökmen, Ş., Topsakal, K. G., & Görgülü, S. (2023). Evaluation of the accuracy of fully automatic cephalometric analysis software with artificial intelligence algorithm. Orthodontics & Craniofacial Research, 26(3), 481-490. https://doi.org/10.1111/ocr.12633

Vancouver

Duran GS, Gökmen Ş, Topsakal KG, Görgülü S. Evaluation of the accuracy of fully automatic cephalometric analysis software with artificial intelligence algorithm. Orthodontics & Craniofacial Research. 2023;26(3):481-490. doi:10.1111/ocr.12633

BibTeX
@article{Duran2023,
  author = {Duran, Gökhan Serhat and Gökmen, Şule and Topsakal, Kübra Gülnur and Görgülü, Serkan},
  title = {Evaluation of the accuracy of fully automatic cephalometric analysis software with artificial intelligence algorithm},
  journal = {Orthodontics & Craniofacial Research},
  year = {2023},
  volume = {26},
  number = {3},
  pages = {481--490},
  doi = {10.1111/ocr.12633}
}
Start for free →