EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Leaf gas exchange measurement for steady‐state stomatal conductance model calibration

Kyle T Rizzo iD, Tong Lei, Thomas N Buckley iD, Brian N Bailey iD

New Phytologist · 2026-04 · 250 (1) · 672-690

DOI: 10.1111/nph.70949 ↗

At a glance

Journal article in New Phytologist, published online on 2026-02-12. Written by Kyle T Rizzo and 3 co-authors. Institution: Department of Plant Sciences, University of California, Davis, Davis, CA, 95616, USA. Major MEDLINE topics: Plant Stomata, Models, Biological, Plant Leaves, Gases. Cited 6 times so far (Crossref); 112 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: National Institute of Food and Agriculture, Division of Integrative Organismal Systems.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Stomatal conductance models are essential components of crop and land surface models, but collecting data to calibrate them remains challenging due to large leaf‐to‐leaf variability, slow stomatal kinetics, and a lack of consistent measurement protocols, leading to unknown reliability and representativeness of calibrated model parameter estimates. We combined field measurements, 3D biophysical simulations, and statistical power analyses to quantify parameter calibration discrepancies with different instruments under different conditions to provide recommendations for protocol development. Leaf‐to‐leaf physiological variability in measured steady‐state stomatal conductance exceeded threefold under identical conditions, calling into question the use of few steady‐state response curves to represent a canopy. Stomatal kinetics introduce systematic error in parameter calibration, and slower stomatal response times necessitated larger survey sample sizes to recover known stomatal model parameters of simulated data. Primary recommendations are as follows: survey measurements ( c. 100 samples) are needed to sample leaf‐to‐leaf variability and can be supplemented by steady‐state measurements to better represent environmental responses, survey measurements should maximize the range of leaf‐level environmental conditions while minimizing transient effects, and steady‐state measurements with controlled environmental conditions should maintain constant conditions for 15–45 min before measurement to allow for true stomatal steady state and not just instrument equilibrium.

Subjects

MeSH terms (MEDLINE)

Plant StomataModels, BiologicalPlant LeavesGasesCalibrationPlant TranspirationKinetics

Author keywords

gas exchangemodel calibrationporometerprotocolstomatal conductance

Substances

Gases

Authors and institutions

  • Department of Plant Sciences, University of California, Davis, Davis, CA, 95616, USA.

ORCID profiles: Kyle T Rizzo, Thomas N Buckley, Brian N Bailey

Funding

  • National Institute of Food and Agriculture
  • Division of Integrative Organismal Systems

Cite

APA

Rizzo, K. T., Lei, T., Buckley, T. N., & Bailey, B. N. (2026). Leaf gas exchange measurement for steady‐state stomatal conductance model calibration. New Phytologist, 250(1), 672-690. https://doi.org/10.1111/nph.70949

Vancouver

Rizzo KT, Lei T, Buckley TN, Bailey BN. Leaf gas exchange measurement for steady‐state stomatal conductance model calibration. New Phytologist. 2026;250(1):672-690. doi:10.1111/nph.70949

BibTeX
@article{Rizzo2026,
  author = {Rizzo, Kyle T and Lei, Tong and Buckley, Thomas N and Bailey, Brian N},
  title = {Leaf gas exchange measurement for steady‐state stomatal conductance model calibration},
  journal = {New Phytologist},
  year = {2026},
  volume = {250},
  number = {1},
  pages = {672--690},
  doi = {10.1111/nph.70949}
}