EUVIMEDObjevte EUVIMED
LeserbriefKommentar

Reconciling discrepancies in measurements of vulnerability to xylem embolism with the pneumatic method

Mauro Brum iD, Luciano Pereira iD, Rafael Vasconcelos Ribeiro iD, Steven Jansen iD, Paulo R L Bittencourt iD, Rafael S Oliveira iD, Scott R Saleska iD

New Phytologist · 2023

DOI: 10.1111/nph.18531 ↗

At a glance

Leserbrief in New Phytologist, 2023. Written by Mauro Brum and 6 co-authors. Institution: Department of Ecology and Evolutionary Biology, University of Arizona, Tucson, AZ, 85721-0088, USA. Major MEDLINE topics: Trees, Embolism. Cited 11 times so far (Crossref); 40 references. Funded by: Deutsche Forschungsgemeinschaft, Fundação de Amparo à Pesquisa do Estado de São Paulo, National Science Foundation of Sri Lanka.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Reconciling discrepancies in measurements of vulnerability to xylem embolism with the pneumatic method A comment on Chen et al. (2021) 'Quantifying vulnerability to embolism in tropical trees and lianas using five methods: can discrepancies be explained by xylem structural traits?' Chen et al. (2021) reported discrepancies between pneumatic and other methods for measuring embolism vulnerability in plant xylem tissue, leading them to caution against using the pneumatic method.We show that this discrepancy arises from faulty implementation: failing to measure air discharge to sufficiently negative water potentials, they under-estimated maximum air discharge (AD max ), and hence embolism resistance.Embolism vulnerability methods identify how dehydrated a stem must become (in water potential, P 50 ) to cause a 50% loss in xylem conductivity.Pneumatic methods require measurements to water potentials roughly twice as dehydrated as P 50 .Yet Chen et al. often stopped at magnitudes even less than what other methods showed P 50 to be, making it mathematically impossible for their pneumatic implementation to measure true P 50 .Our simulations confirmed that premature stopping causes large errors in derived P 50 , accounting for reported discrepancies.Further, literature studies show consistent agreement between pneumatic and other methods.Thus, Chen et al.'s pneumatic results are invalid, and should not be taken to undermine confidence in pneumatic measurements.We recommend best practices, including the 'Pneumatron' for automated measurements, that prevent the errors of Chen et al. and make pneumatic measurements of embolism vulnerability that are fast, replicable, and accurate.

Subjects

MeSH terms (MEDLINE)

TreesEmbolismXylemWaterDroughtsPlant Leaves

Author keywords

cavitationdroughtphenotypingtree mortalitywater

Substances

Water

Authors and institutions

  • Department of Ecology and Evolutionary Biology, University of Arizona, Tucson, AZ, 85721-0088, USA.
  • Institute of Systematic Botany and Ecology, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
  • Laboratory of Crop Physiology, Department of Plant Biology, Institute of Biology, University of Campinas (UNICAMP), PO Box 6109, 13083-970, Campinas, SP, Brazil.
  • College of Life and Environmental Sciences, University of Exeter, Exeter, EX4 4RJ, UK.
  • Department of Plant Biology, Institute of Biology, UNICAMP, PO Box 6109, 13083-970, Campinas, SP, Brazil.

ORCID profiles: Mauro Brum, Luciano Pereira, Rafael Vasconcelos Ribeiro, Steven Jansen, Paulo R L Bittencourt, Rafael S Oliveira, Scott R Saleska

Funding

  • Deutsche Forschungsgemeinschaft
  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • National Science Foundation of Sri Lanka
  • Natural Environment Research Council

Cite

APA

Brum, M., Pereira, L., Ribeiro, R. V., Jansen, S., Bittencourt, P. R. L., Oliveira, R. S., & Saleska, S. R. (2023). Reconciling discrepancies in measurements of vulnerability to xylem embolism with the pneumatic method. New Phytologist. https://doi.org/10.1111/nph.18531

Vancouver

Brum M, Pereira L, Ribeiro RV, Jansen S, Bittencourt PRL, Oliveira RS, et al. Reconciling discrepancies in measurements of vulnerability to xylem embolism with the pneumatic method. New Phytologist. 2023. doi:10.1111/nph.18531

BibTeX
@article{Brum2023,
  author = {Brum, Mauro and Pereira, Luciano and Ribeiro, Rafael Vasconcelos and Jansen, Steven and Bittencourt, Paulo R L and Oliveira, Rafael S and Saleska, Scott R},
  title = {Reconciling discrepancies in measurements of vulnerability to xylem embolism with the pneumatic method},
  journal = {New Phytologist},
  year = {2023},
  doi = {10.1111/nph.18531}
}
Start for free →