EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of Novice Raters for Esophageal Motility Classifications Using Functional Lumen Imaging Probe Panometry

Cayla E Bales, Anthony J Kang, Jacob M Schauer, Keerthana Chakka, Benjamin M Moy, Chiagoziem Ogbonna, Amanda Pirola, Aidan Smires, Mark A Solinski, Rena Yadlapati, John E Pandolfino, Dustin A Carlson

Neurogastroenterology & Motility · 2026-07 · 38 (7)

DOI: 10.1111/nmo.70386 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurogastroenterology & Motility, online erschienen am 05.07.2026. Verfasst von Cayla E Bales und 11 weiteren Autor:innen. Beteiligte Einrichtung: Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School o…. Hauptthemen laut MEDLINE: Esophageal Motility Disorders, Clinical Competence. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDDK NIH HHS, National Institute of Diabetes and Digestive and Kidney Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Functional lumen imaging probe (FLIP) Panometry classifies esophageal motility using esophagogastric junction (EGJ) opening and esophageal contractile patterns. A previous study evaluated FLIP Panometry interpretation among esophageal specialists (which demonstrated an average accuracy of 78% for FLIP motility diagnoses), but the interpretation performance of nonexperts remains unknown. This study aimed to assess the accuracy and interrater agreement of novice raters using FLIP Panometry v1.0 and the novel v2.0 (Dallas Consensus) motility classification schemes.

Methods

Eight non‐gastroenterology trainees without previous FLIP or esophageal motility experience interpreted 40 FLIP studies. Brief training included a video tutorial and review of 10 practice studies with an esophageal specialist. Accuracy was assessed using percent agreement with the reference standard assigned by two experienced raters. Interrater agreement was assessed using intraclass correlation coefficient (ICC) and Fleiss' kappa.

Results

Accuracy of motility diagnosis was mean (95% CI) 0.73 (0.68–0.78) for v2.0 and 0.78 (0.73–0.82) for v1.0. Accuracies ≥ 78% were achieved by four raters for v2.0 and five for v1.0, while other raters' accuracies ranged from 55% to 75%. Accuracy for EGJ opening classification was 0.80 (0.75–0.84) and for contractile response pattern was 0.78 (0.74–0.83) for v2.0 and 0.78 (0.74–0.83) for v1.0. Moderate‐to‐good interrater agreement was observed (ICC 0.80–0.83; kappa 0.55–0.61).

Conclusion

Following brief training, some novice raters achieved accuracy akin to esophageal motility specialists when interpreting FLIP Panometry motility studies. While variation in accuracy highlights the need for improved and adequate training methods for esophageal motility interpretation, accurate FLIP Panometry interpretation was achievable among nonspecialists, supporting feasibility for broad use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Esophageal Motility DisordersClinical CompetenceHumansObserver VariationManometryEsophagusEsophagogastric JunctionReproducibility of Results

Stichwörter der Autor:innen

achalasiadysphagiaendoscopyimpedancemotility

Autor:innen und Institutionen

  • Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Division of Biostatistics and Informatics, Department of Preventive Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Division of Gastroenterology, University of California San Diego, San Diego, California, USA.

Förderung

  • NIDDK NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases

Zitieren

APA

Bales, C. E., Kang, A. J., Schauer, J. M., Chakka, K., Moy, B. M., Ogbonna, C., Pirola, A., Smires, A., Solinski, M. A., Yadlapati, R., Pandolfino, J. E., & Carlson, D. A. (2026). Accuracy of Novice Raters for Esophageal Motility Classifications Using Functional Lumen Imaging Probe Panometry. Neurogastroenterology & Motility, 38(7). https://doi.org/10.1111/nmo.70386

Vancouver

Bales CE, Kang AJ, Schauer JM, Chakka K, Moy BM, Ogbonna C, et al. Accuracy of Novice Raters for Esophageal Motility Classifications Using Functional Lumen Imaging Probe Panometry. Neurogastroenterology & Motility. 2026;38(7). doi:10.1111/nmo.70386

BibTeX
@article{Bales2026,
  author = {Bales, Cayla E and Kang, Anthony J and Schauer, Jacob M and Chakka, Keerthana and Moy, Benjamin M and Ogbonna, Chiagoziem and Pirola, Amanda and Smires, Aidan and Solinski, Mark A and Yadlapati, Rena and Pandolfino, John E and Carlson, Dustin A},
  title = {Accuracy of Novice Raters for Esophageal Motility Classifications Using Functional Lumen Imaging Probe Panometry},
  journal = {Neurogastroenterology & Motility},
  year = {2026},
  volume = {38},
  number = {7},
  doi = {10.1111/nmo.70386}
}
Kostenlos starten →