Assessing mechanical function of peristalsis with functional lumen imaging probe panometry: Contraction power and displaced volume
Neurogastroenterology & Motility · 2023
DOI: 10.1111/nmo.14692 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurogastroenterology & Motility, 2023. Verfasst von Sourav Halder und 9 weiteren Autor:innen. Beteiligte Einrichtung: Theoretical and Applied Mechanics Program, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA. Hauptthemen laut MEDLINE: Peristalsis, Esophageal Motility Disorders. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIDDK NIH HHS, National Institute of Diabetes and Digestive and Kidney Diseases.
Abstract (Originalsprache)
Background and Aims The distal contractile integral (DCI) quantifies the contractile vigor of primary peristalsis on high‐resolution manometry (HRM), whereas no such metric exists for secondary peristalsis on functional lumen imaging probe (FLIP) panometry. This study aimed to evaluate novel FLIP metrics of contraction power and displaced volume in asymptomatic controls and a patient cohort.
Methods
Thirty‐five asymptomatic controls and adult patients (with normal esophagogastric junction outflow/opening and without spasm) who completed HRM and FLIP panometry were included. The patient group also completed timed barium esophagram (TBE). Contraction power (estimate of esophageal work over time) and displaced volume (estimate of contraction‐associated fluid flow) were computed from FLIP. HRM was analyzed per Chicago Classification v4.0. Key Results In controls, median (5th–95th percentile) contraction power was 27 mW (10–44) and displaced volume was 43 mL (17–66). 95 patients were included: 72% with normal motility on HRM, 17% with ineffective esophageal motility (IEM), and 12% with absent contractility. Among patients, DCI was significantly correlated with both contraction power (rho = 0.499) and displaced volume (rho = 0.342); p values < 0.001. Both contraction power and displaced volume were greater in patients with normal motility versus IEM or absent contractility, complete versus incomplete bolus transit, and normal versus abnormal retention on TBE; p values < 0.02.
Conclusions
FLIP panometry metrics of contraction power and displaced volume appeared to effectively quantify peristaltic vigor. These novel metrics may enhance evaluation of esophageal motility with FLIP panometry and provide a reliable surrogate to DCI on HRM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Theoretical and Applied Mechanics Program, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA.
- Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Division of Gastroenterology and Hepatology, Department of Medicine, Northwestern University, Chicago, Illinois, USA.
- Division of Gastroenterology, Department of Medicine, Mayo Clinic, Jacksonville, Florida, USA.
- Division of Biostatistics, Department of Preventive Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
- Department of Gastroenterology, Hospital Clínic de Barcelona, Barcelona, Spain.
- Department of Mechanical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA.
ORCID-Profile: Peter J Kahrilas, Andree Koop, Wenjun Kou, Dustin A Carlson
Förderung
- NIDDK NIH HHS
- National Institute of Diabetes and Digestive and Kidney Diseases
Zitieren
APA
Halder, S., Pandolfino, J. E., Kahrilas, P. J., Koop, A., Schauer, J., Araujo, I. K., Elisha, G., Kou, W., Patankar, N. A., & Carlson, D. A. (2023). Assessing mechanical function of peristalsis with functional lumen imaging probe panometry: Contraction power and displaced volume. Neurogastroenterology & Motility. https://doi.org/10.1111/nmo.14692
Vancouver
Halder S, Pandolfino JE, Kahrilas PJ, Koop A, Schauer J, Araujo IK, et al. Assessing mechanical function of peristalsis with functional lumen imaging probe panometry: Contraction power and displaced volume. Neurogastroenterology & Motility. 2023. doi:10.1111/nmo.14692
BibTeX
@article{Halder2023,
author = {Halder, Sourav and Pandolfino, John E and Kahrilas, Peter J and Koop, Andree and Schauer, Jacob and Araujo, Isis K and Elisha, Guy and Kou, Wenjun and Patankar, Neelesh A and Carlson, Dustin A},
title = {Assessing mechanical function of peristalsis with functional lumen imaging probe panometry: Contraction power and displaced volume},
journal = {Neurogastroenterology & Motility},
year = {2023},
doi = {10.1111/nmo.14692}
}
EUVIMED