Evaluation of a Modified London Protocol to Diagnose Defecation Disorders With High‐Definition Anorectal Manometry

Christian Lambiase iD, Giuseppe Chiarioni, Francesco Rettura, Antonio Grosso, Riccardo Tedeschi, Lorenzo Cancelli, Andrea Bottari, Riccardo Morganti, Nicola de Bortoli iD, Massimo Bellini

Neurogastroenterology & Motility · 2025-12 · 37 (12)

DOI: 10.1111/nmo.70197 ↗

At a glance

Vergleichsstudie in Neurogastroenterology & Motility, published online on 2025-11-03. Written by Christian Lambiase and 9 co-authors. Institution: Gastrointestinal Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy. Major MEDLINE topics: Manometry, Fecal Incontinence, Constipation, Clinical Protocols. 31 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Anorectal manometry (ARM) is useful to diagnose defecation disorders. The International Anorectal Physiology Working Group (IAPWG) introduced a standardized sequence of maneuvers into clinical practice to perform ARM (London Protocol). Regarding the “push” maneuver, excellent consensus among IAPWG experts was limited to the number of pushes and the interval between them. The aim of this study was to assess the diagnostic accuracy of simplified ARM protocols featuring various combinations of different push durations (15, 10 or 5 s) and numbers of push attempts (two or three).

Methods

High‐Definition ARM (HD‐ARM) tracings from 142 patients (113 females, mean aged 54.7 ± 16.9) who underwent ARM for fecal incontinence ( n = 37) or constipation ( n = 105) were retrospectively reviewed. HD‐ARM tracings were re‐evaluated based on the following modifications to the London protocol: considering only the first two pushes; considering the first ten seconds of each push; considering the first ten seconds of the first two pushes; considering the first five seconds of each push; considering the first five seconds of the first two pushes. HD‐ARM reports were redrawn because of these protocol modifications and were compared with the reports obtained using the IAPGW standard protocol in terms of manometric pattern and diagnosis.

Results

The proposed modified protocols featuring ten‐ or fifteen‐second pushes showed an almost perfect concordance compared with the standard of practice ( k = 0.97), while the modified protocols featuring 5 s pushes showed only a fair/moderate diagnostic concordance. The latter was mainly linked to a transient increase in anal pressure (lasting on average four to five seconds).

Conclusions

Based on our results, two push efforts of ten seconds each may be enough to reach an accurate manometric diagnosis of defecation disorders. Five‐second push may not be sufficient given the transient increase in anal pressure at the beginning of the push attempt. Performing only two push maneuvers of ten seconds each may reduce by 55 s the length of this cumbersome examination.

Subjects

MeSH terms (MEDLINE)

ManometryFecal IncontinenceConstipationClinical ProtocolsHumansMaleFemaleAdultMiddle AgedAgedRetrospective StudiesPressureTime FactorsDefecationRectum

Author keywords

London Protocolanorectal manometrychronic constipationdyssynergic defecationfecal incontinencefunctional defecation disorders

Authors and institutions

  • Gastrointestinal Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.
  • Regional Center for Functional and Motility Digestive Disorders, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
  • UNC Center for Functional GI and Motility Disorders, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Il Cerchio Med HealthCare, Verona Center, Verona, Italy.
  • Gastroenterology Unit, Annunziata Hospital, AOCS, Cosenza, Italy.
  • Clinical Trial Statistical Support Unit, Azienda Ospedaliero Universitaria Pisana, Pisa, Italy.

ORCID profiles: Christian Lambiase, Nicola de Bortoli

Cite

APA

Lambiase, C., Chiarioni, G., Rettura, F., Grosso, A., Tedeschi, R., Cancelli, L., Bottari, A., Morganti, R., de Bortoli, N., & Bellini, M. (2025). Evaluation of a Modified London Protocol to Diagnose Defecation Disorders With High‐Definition Anorectal Manometry. Neurogastroenterology & Motility, 37(12). https://doi.org/10.1111/nmo.70197

Vancouver

Lambiase C, Chiarioni G, Rettura F, Grosso A, Tedeschi R, Cancelli L, et al. Evaluation of a Modified London Protocol to Diagnose Defecation Disorders With High‐Definition Anorectal Manometry. Neurogastroenterology & Motility. 2025;37(12). doi:10.1111/nmo.70197

BibTeX
@article{Lambiase2025,
  author = {Lambiase, Christian and Chiarioni, Giuseppe and Rettura, Francesco and Grosso, Antonio and Tedeschi, Riccardo and Cancelli, Lorenzo and Bottari, Andrea and Morganti, Riccardo and de Bortoli, Nicola and Bellini, Massimo},
  title = {Evaluation of a Modified London Protocol to Diagnose Defecation Disorders With High‐Definition Anorectal Manometry},
  journal = {Neurogastroenterology & Motility},
  year = {2025},
  volume = {37},
  number = {12},
  doi = {10.1111/nmo.70197}
}
Start for free →