EUVIMEDEUVIMED entdecken
Multizentrische Studie

Associations between bioelectrical impedance analysis‐derived phase angle, protein‐energy wasting and all‐cause mortality in older patients undergoing haemodialysis

Sho Kojima iD, Naoto Usui, Akimi Uehata, Akihito Inatsu, Atsuhiro Tsubaki

Nephrology · 2024

DOI: 10.1111/nep.14333 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Nephrology, 2024. Verfasst von Sho Kojima und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation, Kisen Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Electric Impedance, Renal Dialysis, Protein-Energy Malnutrition, Predictive Value of Tests. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Protein‐energy wasting (PEW) is a common syndrome in patients undergoing haemodialysis (HD) and is associated with poor prognosis. Bioelectrical impedance analysis (BIA)‐derived phase angle (PA) is useful for predicting PEW, but sex and age need to be considered. We aimed to reveal sex‐specific cut‐off values of PA predicting PEW in HD patients aged ≥65.

Methods

This two‐centre retrospective cohort study included patients on HD who underwent BIA. PEW was detected using the International Society of Renal Nutrition and Metabolism (ISRNM) criteria as a reference. The PA was measured using a multifrequency bioimpedance device. Sex‐specific cut‐off values of PA predicting PEW were detected by receiver‐operator characteristic analysis. We investigated the association between PEW determined using sex‐specific cut‐off values for PA and all‐cause mortality.

Results

This study included 274 patients undergoing HD, with a median age of 75 (70–80) years, mean PA of 3.8 ± 1.1° and PEW of 43%. Over a median follow‐up duration of 1095 (400–1095) days, 111 patients died. Cut‐off values of PA predicting PEW were as follows: female, 3.00° (sensitivity, 87.3%; specificity, 77.5%), and male, 3.84° (sensitivity, 77.6%; specificity, 71.4%). The kappa coefficient between sex‐specific cut‐off values of the PA and ISRNM criteria had a moderate coincidence level of 0.55. PEW detected by PA was independently associated with all‐cause mortality (hazard ratio: 2.40; 95% confidence interval: 1.51–3.85; p < .001).

Conclusions

Sex‐specific cut‐off values for PA in older HD patients may be useful as a screening tool for predicting PEW and mortality. image

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceRenal DialysisProtein-Energy MalnutritionPredictive Value of TestsHumansMaleAgedFemaleRetrospective StudiesAged, 80 and overRisk FactorsAge FactorsSex FactorsBody CompositionCause of DeathNutritional StatusTreatment OutcomeTime Factors

Stichwörter der Autor:innen

bioelectrical impedance analysishaemodialysisolderphase angleprotein‐energy wastingsex difference

Autor:innen und Institutionen

  • Department of Rehabilitation, Kisen Hospital, Tokyo, Japan.
  • Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan.
  • Department of Nephrology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
  • Division of Cardiology, Kisen Hospital, Tokyo, Japan.
  • Division of Nephrology, Kisen Hospital, Tokyo, Japan.

ORCID-Profile: Sho Kojima

Zitieren

APA

Kojima, S., Usui, N., Uehata, A., Inatsu, A., & Tsubaki, A. (2024). Associations between bioelectrical impedance analysis‐derived phase angle, protein‐energy wasting and all‐cause mortality in older patients undergoing haemodialysis. Nephrology. https://doi.org/10.1111/nep.14333

Vancouver

Kojima S, Usui N, Uehata A, Inatsu A, Tsubaki A. Associations between bioelectrical impedance analysis‐derived phase angle, protein‐energy wasting and all‐cause mortality in older patients undergoing haemodialysis. Nephrology. 2024. doi:10.1111/nep.14333

BibTeX
@article{Kojima2024,
  author = {Kojima, Sho and Usui, Naoto and Uehata, Akimi and Inatsu, Akihito and Tsubaki, Atsuhiro},
  title = {Associations between bioelectrical impedance analysis‐derived phase angle, protein‐energy wasting and all‐cause mortality in older patients undergoing haemodialysis},
  journal = {Nephrology},
  year = {2024},
  doi = {10.1111/nep.14333}
}
Kostenlos starten →