EUVIMEDEUVIMED entdecken
Crossref

Potential Role for Using Bioimpedance to Reduce the Risk of Intra‐Dialytic Hypotension

Sabrina Haroon iD, Andrew Davenport

Artificial Organs · 2025

DOI: 10.1111/aor.14999 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Sabrina Haroon und 1 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, National University Hospital, Singapore, Singapore. Hauptthemen laut MEDLINE: Hypotension, Renal Dialysis, Electric Impedance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intra‐dialytic hypotension is the most common complication of hemodialysis treatments. Traditionally, clinical judgment determines the post‐dialysis target weight and ultrafiltration volumes. We examined the role of pre‐dialysis bioimpedance measurements and subsequent intradialytic hypotension.

Methods

Segmental bioimpedance measurements were taken pre‐dialysis from hemodialysis outpatients who had been acutely admitted to the hospital, with dialysis prescriptions and ultrafiltration targets determined by the clinical team.

Results

We studied 42 patients with a mean age of 66.9 ± 12.5 years. Among 28 patients (66.7%) that developed intradialytic hypotension, the group had shorter stature (163.9 ± 8.8 vs. 170.1 ± 7.8 cm, p < 0.05), and lower N‐terminal brain natriuretic peptide levels (11 269 (3523–33 843) vs. 28 454 (4957–59 867) pg/mL, p < 0.05). The extracellular water to intracellular water ratio for the whole body was lower in the intradialytic hypotension group (68.0 ± 3.9 vs. 70.5 ± 3.4, p < 0.05), and the relative extracellular to intracellular ratios were lower when the trunk, right leg, and left leg were compared to the left arm ( p < 0.01). Multivariable analysis showed that intradialytic hypotension was associated with the extracellular to intracellular ratio of the trunk compared to the ratio in the left arm (odds ratio 0.80, p = 0.01) and height (odds ratio 0.88 p = 0.03).

Conclusion

We found that hemodialysis patients acutely admitted to hospital with a relatively lower extracellular to intracellular ratio of trunk compared to a similar ratio in the left arm had a greater incidence of intradialytic hypotension. As such, reviewing segmental bioimpedance may aid clinical assessments of patients in setting ultrafiltration volumes and post‐dialysis target weights and prevent intradialytic hypotension.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypotensionRenal DialysisElectric ImpedanceHumansMaleAgedFemaleMiddle AgedRisk FactorsAged, 80 and overKidney Failure, Chronic

Stichwörter der Autor:innen

bioelectrical impedance analysishemodialysisintradialytic hypotension

Autor:innen und Institutionen

  • Division of Nephrology, National University Hospital, Singapore, Singapore.
  • UCL Centre for Kidney and Bladder Health, Royal Free Hospital, Division of Medicine, University College London, London, UK.

ORCID-Profile: Sabrina Haroon

Zitieren

APA

Haroon, S., & Davenport, A. (2025). Potential Role for Using Bioimpedance to Reduce the Risk of Intra‐Dialytic Hypotension. Artificial Organs. https://doi.org/10.1111/aor.14999

Vancouver

Haroon S, Davenport A. Potential Role for Using Bioimpedance to Reduce the Risk of Intra‐Dialytic Hypotension. Artificial Organs. 2025. doi:10.1111/aor.14999

BibTeX
@article{Haroon2025,
  author = {Haroon, Sabrina and Davenport, Andrew},
  title = {Potential Role for Using Bioimpedance to Reduce the Risk of Intra‐Dialytic Hypotension},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.14999}
}
Kostenlos starten →