Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient
Microcirculation · 2024
DOI: 10.1111/micc.12873 ↗At a glance
Journal article in Microcirculation, 2024. Written by Christopher D Bertram and 1 co-authors. Institution: School of Mathematics and Statistics, University of Sydney, New South Wales, Australia. Major MEDLINE topics: Lymphatic Vessels, Homeodomain Proteins, Tumor Suppressor Proteins. 28 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NHLBI NIH HHS, National Institutes of Health.
Abstract (original language)
Objective
Intravascular lymphatic valves often occur in proximity to vessel junctions. It is commonly held that disturbed flow at junctions is responsible for accumulation of valve‐forming cells (VFCs) at these locations as the initial step in valve creation, and the one which explains the association with these sites. However, evidence in favor is largely limited to cell culture experiments.
Methods
We acquired images of embryonic lymphatic vascular networks from day E16.5, when VFC accumulation has started but the developing valve has not yet altered the local vessel geometry, stained for Prox1, which co‐localizes with Foxc2. Using finite‐element computational fluid mechanics, we simulated the flow through the networks, under conditions appropriate to this early development stage. Then we correlated the Prox1 distributions with the distributions of simulated fluid shear and shear stress gradient.
Results
Across a total of 16 image sets, no consistent correlation was found between Prox1 distribution and the local magnitude of fluid shear, or its positive or negative gradient.
Conclusions
This, the first direct semi‐empirical test of the localization hypothesis to interrogate the tissue from in vivo at the critical moment of development, does not support the idea that a feature of the local flow determines valve localization.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- School of Mathematics and Statistics, University of Sydney, New South Wales, Australia.
ORCID profiles: Christopher D Bertram, Charlie Macaskill
Funding
- NHLBI NIH HHS
- National Institutes of Health
Cite
APA
Bertram, C. D., & Macaskill, C. (2024). Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient. Microcirculation. https://doi.org/10.1111/micc.12873
Vancouver
Bertram CD, Macaskill C. Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient. Microcirculation. 2024. doi:10.1111/micc.12873
BibTeX
@article{Bertram2024,
author = {Bertram, Christopher D and Macaskill, Charlie},
title = {Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient},
journal = {Microcirculation},
year = {2024},
doi = {10.1111/micc.12873}
}
EUVIMED