Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient
Microcirculation · 2024
DOI: 10.1111/micc.12873 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microcirculation, 2024. Verfasst von Christopher D Bertram und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Statistics, University of Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Lymphatic Vessels, Homeodomain Proteins, Tumor Suppressor Proteins. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Objective
Intravascular lymphatic valves often occur in proximity to vessel junctions. It is commonly held that disturbed flow at junctions is responsible for accumulation of valve‐forming cells (VFCs) at these locations as the initial step in valve creation, and the one which explains the association with these sites. However, evidence in favor is largely limited to cell culture experiments.
Methods
We acquired images of embryonic lymphatic vascular networks from day E16.5, when VFC accumulation has started but the developing valve has not yet altered the local vessel geometry, stained for Prox1, which co‐localizes with Foxc2. Using finite‐element computational fluid mechanics, we simulated the flow through the networks, under conditions appropriate to this early development stage. Then we correlated the Prox1 distributions with the distributions of simulated fluid shear and shear stress gradient.
Results
Across a total of 16 image sets, no consistent correlation was found between Prox1 distribution and the local magnitude of fluid shear, or its positive or negative gradient.
Conclusions
This, the first direct semi‐empirical test of the localization hypothesis to interrogate the tissue from in vivo at the critical moment of development, does not support the idea that a feature of the local flow determines valve localization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mathematics and Statistics, University of Sydney, New South Wales, Australia.
ORCID-Profile: Christopher D Bertram, Charlie Macaskill
Förderung
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Bertram, C. D., & Macaskill, C. (2024). Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient. Microcirculation. https://doi.org/10.1111/micc.12873
Vancouver
Bertram CD, Macaskill C. Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient. Microcirculation. 2024. doi:10.1111/micc.12873
BibTeX
@article{Bertram2024,
author = {Bertram, Christopher D and Macaskill, Charlie},
title = {Fluid‐Dynamic Modeling of Flow in Embryonic Tissue Indicates That Lymphatic Valve Location Is Not Consistently Determined by the Local Fluid Shear or Its Gradient},
journal = {Microcirculation},
year = {2024},
doi = {10.1111/micc.12873}
}
EUVIMED