EUVIMEDSkopri EUVIMED
Open access · CC BY-NC-ND 4.0

A novel placement method of a calibration-free pH capsule for continuous wireless measurement of intragastric pH in horses

Evelyn Hodgson iD, Marthe Thirouin iD, Pranav Narayanan, Tallia-Rume Romano, Jessica Wise iD, Stephanie Bond iD

Journal of Veterinary Internal Medicine · 2025-01-01 · 39 (1)

DOI: 10.1111/jvim.17273 ↗

At a glance

Journal article in Journal of Veterinary Internal Medicine, published online on 2025-01-01. Written by Evelyn Hodgson and 5 co-authors. Institution: School of Veterinary Science, Faculty of Science, University of Queensland, Gatton, Queensland 4343, Australia. Major MEDLINE topics: Wireless Technology. Cited 4 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Building Industry Research Relationships in Science and Translation (BIRRST), The University of Queensland, Adam Gillespie Memorial Scholarship for Animal Husbandry, Open access publishing facilitated by The University of Queensland, as part of the Wiley - The University of Queensland agreement via the Council of Australian….

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Current methods to measure intragastric pH in horses have limitations. A wireless capsule has been designed for continuous esophageal pH monitoring in humans.

Objectives

To (1) determine the feasibility and describe the methodology of measuring intragastric pH wirelessly in horses; and (2) determine attachment duration of the capsules. Animals Eleven healthy adult horses.

Methods

Capsules were attached to squamous and glandular gastric mucosa under gastroscopic guidance, using suture loops and 1 to 4 hemostasis clips. pH was continuously recorded using a wireless recorder in both fed and fasted states. Gastroscopy was performed daily to assess capsule attachment and any mucosal damage. Data were analyzed using commercially available software. Values are reported as median (interquartile range).

Results

Capsules were successfully placed and data obtained in squamous (n = 11) and glandular (n = 7) regions. The overall duration of squamous capsule attachment was 27 hours (15-32); 1 clip (n = 4) was 15 hours (11-20), 2 clips (n = 2) was 20 hours (16-23), 3 clips (n = 4) was 32 hours (30-32), and 4 clips (n = 1) was 33 hours. The overall duration of glandular capsule attachment was 10 hours (8-21); 1 clip (n = 2) was 11 hours (10-13), 2 clips (n = 2) was 19 hours (14-23), 3 clips (n = 2) was 7 hours (7-8), and 4 clips (n = 1) was 158 hours. There was no substantial damage to the gastric mucosa as a consequence of attachment. Conclusions and Clinical Importance This novel technique enables the wireless measurement of intragastric pH in horses at known locations under fed and fasted conditions, providing a viable alternative for continuous monitoring in both research and clinical scenarios.

Subjects

MeSH terms (MEDLINE)

Wireless TechnologyAnimalsHorsesHydrogen-Ion ConcentrationMaleFemaleGastric Acidity DeterminationGastroscopyStomach

Author keywords

EGGDEGUSESGDequinegastriculcers

Authors and institutions

  • School of Veterinary Science, Faculty of Science, University of Queensland, Gatton, Queensland 4343, Australia.

ORCID profiles: Evelyn Hodgson, Marthe Thirouin, Jessica Wise, Stephanie Bond

Funding

  • Building Industry Research Relationships in Science and Translation (BIRRST), The University of Queensland
  • Adam Gillespie Memorial Scholarship for Animal Husbandry
  • Open access publishing facilitated by The University of Queensland, as part of the Wiley - The University of Queensland agreement via the Council of Australian…

Cite

APA

Hodgson, E., Thirouin, M., Narayanan, P., Romano, T. R., Wise, J., & Bond, S. (2025). A novel placement method of a calibration-free pH capsule for continuous wireless measurement of intragastric pH in horses. Journal of Veterinary Internal Medicine, 39(1). https://doi.org/10.1111/jvim.17273

Vancouver

Hodgson E, Thirouin M, Narayanan P, Romano TR, Wise J, Bond S. A novel placement method of a calibration-free pH capsule for continuous wireless measurement of intragastric pH in horses. Journal of Veterinary Internal Medicine. 2025;39(1). doi:10.1111/jvim.17273

BibTeX
@article{Hodgson2025,
  author = {Hodgson, Evelyn and Thirouin, Marthe and Narayanan, Pranav and Romano, Tallia-Rume and Wise, Jessica and Bond, Stephanie},
  title = {A novel placement method of a calibration-free pH capsule for continuous wireless measurement of intragastric pH in horses},
  journal = {Journal of Veterinary Internal Medicine},
  year = {2025},
  volume = {39},
  number = {1},
  doi = {10.1111/jvim.17273}
}
Start for free →