Comparison of atlantoaxial and lumbosacral cerebrospinal fluid centesis techniques in South American camelids
Journal of Veterinary Internal Medicine · 2024
DOI: 10.1111/jvim.17023 ↗At a glance
Journal article in Journal of Veterinary Internal Medicine, 2024. Written by Ester Malmström and 4 co-authors. Institution: Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Evenstad, Norway. Major MEDLINE topics: Paracentesis, Cerebrospinal Fluid. Cited 1 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: College of Veterinary Medicine, Auburn University, Department of Clinical Sciences, College of Veterinary Medicine, Auburn University.
Abstract (original language)
Background
Iatrogenic blood contamination during cerebrospinal fluid (CSF) centesis is common, which can limit the diagnostic usefulness of the sample. A novel ultrasound-guided CSF collection technique is described in horses, by which CSF is obtained from the atlantoaxial (AA) space. Hypothesis/Objectives To compare ultrasound-guided AA centesis with lumbosacral (LS) centesis in South American camelids (SAC). The hypotheses were that AA centesis would yield samples with less blood contamination although being technically more challenging than LS centesis. Animals Eight clinically healthy adult SAC from a university-owned teaching herd.
Methods
Single-blinded, randomized, 4-way, 4-period crossover study in which 2 veterinarians each performed both centesis techniques on each animal once. Cytological sample analysis was performed, and the technical difficulty of sample acquisition was assessed.
Results
The CSF was collected successfully and without complications by either technique during all collection attempts. Aspects of technical difficulty and concentrations of CSF analytes did not vary significantly between techniques. Median total nucleated cell and red blood cell counts were 1/μL and 0.5/μL and 167.5/μL and 155/μL for AA and LS techniques, respectively. The median total protein concentration was 32.9 mg/dL and 38 mg/dL for AA and LS centeses. A median of 1 attempt was necessary for both centesis techniques and the median number of needle repositioning events was 1 for AA and 0 for LS. Conclusion and Clinical Importance Depending on clinical circumstances, ultrasound-guided AA centesis appears to be an acceptable alternative to other techniques for collection of CSF from SAC.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Evenstad, Norway.
- Department of Clinical Sciences, JT Vaughan Large Animal Teaching Hospital, College of Veterinary Medicine, Auburn University, Auburn, Alabama, USA.
- Department of Pathobiology, College of Veterinary Medicine, Auburn University, Auburn, Alabama, USA.
ORCID profiles: Thomas Passler
Funding
- College of Veterinary Medicine, Auburn University
- Department of Clinical Sciences, College of Veterinary Medicine, Auburn University
Cite
APA
Malmström, E., Cole, R. C., Hofmeister, E. H., Stern, J. K., & Passler, T. (2024). Comparison of atlantoaxial and lumbosacral cerebrospinal fluid centesis techniques in South American camelids. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/jvim.17023
Vancouver
Malmström E, Cole RC, Hofmeister EH, Stern JK, Passler T. Comparison of atlantoaxial and lumbosacral cerebrospinal fluid centesis techniques in South American camelids. Journal of Veterinary Internal Medicine. 2024. doi:10.1111/jvim.17023
BibTeX
@article{Malmstrm2024,
author = {Malmström, Ester and Cole, Robert C and Hofmeister, Erik H and Stern, Jere K and Passler, Thomas},
title = {Comparison of atlantoaxial and lumbosacral cerebrospinal fluid centesis techniques in South American camelids},
journal = {Journal of Veterinary Internal Medicine},
year = {2024},
doi = {10.1111/jvim.17023}
}
EUVIMED