Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, online erschienen am 01.07.2023. Verfasst von Femke Mortier und 4 weiteren Autor:innen. Beteiligte Einrichtung: Small Animal Department, Ghent University, Ghent, Belgium. Hauptthemen laut MEDLINE: Urinalysis, Cat Diseases. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Bijzonder Onderzoeksfonds UGent, CEVA Santé Animale, IDEXX Laboratories Inc..
Abstract (Originalsprache)
Background
Urinalysis is necessary for the diagnostic evaluation of chronic kidney disease in cats. Performing cystocentesis is not always feasible, but data comparing urine obtained by cystocentesis in the clinic with voided samples collected at home are lacking in cats.
Objectives
To compare urinary protein:creatinine ratio (UPC) and urine specific gravity (USG) and to detect clinically relevant changes in proteinuria substage or urine concentration between urine collected at home and in-clinic by cystocentesis in cats. Animals Ninety-two healthy and diseased client-owned cats.
Methods
Prospective study. Owners collected voided urine at home and within 1 to 15 hours, cystocentesis was performed in the clinic.
Results
In a subset of motivated owners, 55% succeeded in collecting urine at home. Overall, UPC was higher (mean ±SD difference = 0.09 ±0.22; P < .001) and USG was lower (mean ±SD difference = −0.006 ±0.009; P < .001) in cystocentesis samples than in voided urine. Substantial agreement existed between sampling methods for UPC (weighted к = 0.68) and USG (к = 0.64) categories. A different proteinuria substage (UPC < 0.2, 0.2-0.4, >0.4) was present in paired urine samples from 28% of cats. In 18% of cats, urine concentrating ability (USG < or ≥1.035) differed between both samples. Conclusions and Clinical Importance Home sampling of urine is a valid alternative to cystocentesis in cats. However, because clinically relevant differences in UPC and USG were present in 28% and 18% of cats, respectively, by the same collection method for monitoring each cat is advised.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Small Animal Department, Ghent University, Ghent, Belgium.
- Biometrics Research Center, Ghent University, Ghent, Belgium.
ORCID-Profile: Femke Mortier, Sylvie Daminet, Sofie J J Marynissen, Dominique Paepe
Förderung
- Bijzonder Onderzoeksfonds UGent
- CEVA Santé Animale
- IDEXX Laboratories Inc.
Zitieren
APA
Mortier, F., Daminet, S., Duchateau, L., Marynissen, S. J. J., & Paepe, D. (2023). Comparison of cystocentesis versus home sampling to determine urinary protein: Creatinine ratio and urine specific gravity in cats. Journal of Veterinary Internal Medicine, 37(4), 1401-1408. https://doi.org/10.1111/jvim.16800
Vancouver
Mortier F, Daminet S, Duchateau L, Marynissen SJJ, Paepe D. Comparison of cystocentesis versus home sampling to determine urinary protein: Creatinine ratio and urine specific gravity in cats. Journal of Veterinary Internal Medicine. 2023;37(4):1401-1408. doi:10.1111/jvim.16800
BibTeX
@article{Mortier2023,
author = {Mortier, Femke and Daminet, Sylvie and Duchateau, Luc and Marynissen, Sofie J J and Paepe, Dominique},
title = {Comparison of cystocentesis versus home sampling to determine urinary protein: Creatinine ratio and urine specific gravity in cats},
journal = {Journal of Veterinary Internal Medicine},
year = {2023},
volume = {37},
number = {4},
pages = {1401--1408},
doi = {10.1111/jvim.16800}
}
EUVIMED