A Comparison of Snoring Changes With a Supine‐Avoidance Alarm Device Compared to Constant Positive Airway Pressure Treatment in Patients With Supine‐Predominant OSA
Journal of Sleep Research · 2026
DOI: 10.1111/jsr.70128 ↗At a glance
Randomisierte kontrollierte Studie in Journal of Sleep Research, 2026. Written by Matthew M Rahimi and 3 co-authors. Institution: Flinders Health and Medical Research Institute: Sleep Health, (Formerly Adelaide Institute for Sleep Health), College of Medicine and Public Health, …. Major MEDLINE topics: Snoring, Continuous Positive Airway Pressure, Sleep Apnea, Obstructive. 39 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
This study aimed to quantify how much snoring occurs in patients with supine‐predominant OSA and the comparative effectiveness of supine‐avoidance therapy versus CPAP to reduce objective measures of snoring. Participants had a 1‐week in‐home sleep posture assessment and a in‐home PSG study before being randomised to either CPAP or supine‐avoidance therapy for 6–8 weeks, then switched treatments for another 6–8 weeks. Snoring and treatment outcomes were examined in a subgroup of patients with supine dependent snoring. Baseline measurements showed snoring frequency was 48.9 [95% CI 16.7 to 188.7], 26.3 [95% CI 17.0 to 106.3], 57.5 [95% CI 16.8 to 190.7] snores/h for the whole group, supine snorer and non‐supine snorers respectively. Supine sleep as a percentage of total sleep was almost completely abolished with supine‐avoidance treatment (Baseline = 30.7% [95% 15.4 to 46.4], supine‐avoidance = 0.2% [95% 0.0 to 15.7]). In the whole group, CPAP significantly reduced overall snoring frequency although residual snoring remained. However, no treatment effect was observed with supine‐avoidance therapy in reducing snoring frequency (frequency of snores ≥ 50 dBA; baseline = 48.9 [95% 16.7 to 188.7], supine‐avoidance = 36.8 [95% 6.3 to 233.7], CPAP = 4.2 [95% 2.1 to 29.5] snores/h). In the sub‐group of supine‐predominant snorers, supine‐avoidance therapy was associated with reduced snoring frequency (Baseline = 26.3 [95% 17.0 to 106.3], supine‐avoidance = 14.3 [95% 3.0 to 18.1], CPAP = 4.6 [95% 2.6 to 8.9] snores/h). Supine‐avoidance therapy may not necessarily lead to a systematic reduction of snoring frequency in patients with supine‐predominant OSA but appears effective in a subgroup of patients.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Flinders Health and Medical Research Institute: Sleep Health, (Formerly Adelaide Institute for Sleep Health), College of Medicine and Public Health, Flinders University, Bedford Park, South Australia, Australia.
- Woolcock Institute of Medical Research, Macquarie Park, New South Wales, Australia.
ORCID profiles: Matthew M Rahimi, Andrew Vakulin, David Stevens
Cite
APA
Rahimi, M. M., Vakulin, A., Stevens, D., & Catcheside, P. G. (2026). A Comparison of Snoring Changes With a Supine‐Avoidance Alarm Device Compared to Constant Positive Airway Pressure Treatment in Patients With Supine‐Predominant OSA. Journal of Sleep Research. https://doi.org/10.1111/jsr.70128
Vancouver
Rahimi MM, Vakulin A, Stevens D, Catcheside PG. A Comparison of Snoring Changes With a Supine‐Avoidance Alarm Device Compared to Constant Positive Airway Pressure Treatment in Patients With Supine‐Predominant OSA. Journal of Sleep Research. 2026. doi:10.1111/jsr.70128
BibTeX
@article{Rahimi2026,
author = {Rahimi, Matthew M and Vakulin, Andrew and Stevens, David and Catcheside, Peter G},
title = {A Comparison of Snoring Changes With a Supine‐Avoidance Alarm Device Compared to Constant Positive Airway Pressure Treatment in Patients With Supine‐Predominant OSA},
journal = {Journal of Sleep Research},
year = {2026},
doi = {10.1111/jsr.70128}
}
EUVIMED