Validation of manually scored multichannel frontal electroencephalography against polysomnography in a paediatric cohort
Journal of Sleep Research · 2025
DOI: 10.1111/jsr.70012 ↗At a glance
Validierungsstudie in Journal of Sleep Research, 2025. Written by Sigridur Sigurdardottir and 11 co-authors. Institution: Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland. Major MEDLINE topics: Polysomnography, Electroencephalography, Sleep Stages, Sleep Apnea, Obstructive. Cited 3 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Icelandic Centre for Research, The European Union´s Horizon 2020 Research and Innovation Program, the Scientific Foundation of Respiratory Diseases.
Abstract (original language)
Polysomnography is the only internationally recognized method to diagnose paediatric obstructive sleep apnea, thus, simpler and more cost‐effective diagnostic tools are urgently needed. This study aimed to validate the manual scoring of frontal self‐applicable electroencephalography against polysomnography in a paediatric cohort. The polysomnography and the frontal electroencephalography were simultaneously recorded for 1 night ( n = 102) in 10–13‐year‐old children. Scoring was performed according to the American Academy of Sleep Medicine rules, with minor adjustments to the frontal electroencephalography. Manual scorings of sleep stages were compared in an epoch‐by‐epoch manner using Cohen's kappa (κ) and confusion matrices using three different models: the three‐stage (wake/non‐rapid eye movement/rapid eye movement), the four‐stage (wake/sleep stage 1 + sleep stage 2/deep sleep Stage 3/rapid eye movement) and the five‐stage model (wake/sleep stage 1/sleep stage 2/deep sleep Stage 3/rapid eye movement). The inter‐scorer agreements were assessed, and the intraclass correlation coefficient was used for common sleep variables: total sleep time, wake after sleep onset, sleep efficiency, sleep‐onset latency and arousal index. Cohen's κ values for the three‐stage, four‐stage and five‐stage models were 0.85, 0.73 and 0.70, respectively. The agreement for the sleep variables studied ranged from 0.87 to 0.99. The inter‐rater agreement ( n = 10) was κ = 0.78 for the polysomnography and κ = 0.70 for the frontal electroencephalography. Sleep staging from the frontal electroencephalography was comparable to that of a standard polysomnography in a paediatric cohort, and showed promising results in estimating sleep time and sleep architecture.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland.
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
- Department of Immunology, Landspitali University Hospital, Reykjavik, Iceland.
- University of Iceland, Faculty of Medicine, Reykjavik, Iceland.
- Children's Hospital Reykjavik, Reykjavik, Iceland.
ORCID profiles: Sigridur Sigurdardottir, Henna Pitkänen, Henri Korkalainen, Samu Kainulainen, Timo Leppänen, Erna Sif Arnardottir
Funding
- Icelandic Centre for Research
- The European Union´s Horizon 2020 Research and Innovation Program
- the Scientific Foundation of Respiratory Diseases
- the State Research Funding for university-level health research, Kuopio University Hospital, Wellbeing Service County of North Savo
- NordForsk
- Business Finland
- the Landspitali University Hospital Science Fund
- the Finnish Cultural Foundation - North Savo Regional Fund
Cite
APA
Sigurdardottir, S., Pitkänen, H., Korkalainen, H., Kainulainen, S., Serwatko, M., Olafsdottir, K. A., Sigurðardóttir, S. Þ., Clausen, M., Somaskandhan, P., Stražišar, B. G., Leppänen, T., & Arnardottir, E. S. (2025). Validation of manually scored multichannel frontal electroencephalography against polysomnography in a paediatric cohort. Journal of Sleep Research. https://doi.org/10.1111/jsr.70012
Vancouver
Sigurdardottir S, Pitkänen H, Korkalainen H, Kainulainen S, Serwatko M, Olafsdottir KA, et al. Validation of manually scored multichannel frontal electroencephalography against polysomnography in a paediatric cohort. Journal of Sleep Research. 2025. doi:10.1111/jsr.70012
BibTeX
@article{Sigurdardottir2025,
author = {Sigurdardottir, Sigridur and Pitkänen, Henna and Korkalainen, Henri and Kainulainen, Samu and Serwatko, Marta and Olafsdottir, Kristin A and Sigurðardóttir, Sigurveig Þ and Clausen, Michael and Somaskandhan, Pranavan and Stražišar, Barbara G and Leppänen, Timo and Arnardottir, Erna Sif},
title = {Validation of manually scored multichannel frontal electroencephalography against polysomnography in a paediatric cohort},
journal = {Journal of Sleep Research},
year = {2025},
doi = {10.1111/jsr.70012}
}
EUVIMED