EUVIMEDOpdag EUVIMED
Crossref

Detection frequency, sonoanatomy and reference values of the duodenal papillae and connected anatomical structures in cats

R Leppin iD

Journal of Small Animal Practice · 2025

DOI: 10.1111/jsap.13813 ↗

At a glance

Journal article in Journal of Small Animal Practice, 2025. Written by R Leppin. Institution: Tierklinik Düsseldorf GmbH, Düsseldorf, Germany. Major MEDLINE topics: Ampulla of Vater. 19 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objectives

To describe the detection frequency, sonoanatomy and reference values of the duodenal papillae and connected anatomical structures in cats, with reference to gross anatomical and histopathological nomenclature. Materials and Methods A prospective, case‐controlled study of sonographic examinations of the duodenal papillae in 50 client‐owned cats using an ultrasound device (Logiq E9, GE Healthcare) with a 15 MHz linear transducer.

Results

The major duodenal papilla was found in 100% of cases, the minor duodenal papilla in 10%. The common bile duct and the main pancreatic duct could be traced to the duodenum in all of the cats. After an extramural part, in which the two ducts extend in a parallel fashion, they entered the duodenal wall. The subsequent intramural part was divided into three sections: the portio infundibularis, the portio submucosa and the major duodenal papilla. The 27 clinically healthy cats had a mean portio infundibularis length, width, and height in mm of 3.7, 2.5 and 2.2, respectively. These dimensions were 3.5, 2.1, 2.9 for the portio submucosa and 0.5, 2.1, 2.9 for the major duodenal papilla. Calculi in the major duodenal papilla were found in 12% of the cats. The course of the accessory pancreatic duct from the pancreas through the MIDP into the duodenum was documented. Clinical Significance The ultrasonographic examination of the duodenal papillae is easy to perform and it can be considered part of the routine examination for feline patients presenting with relevant clinical signs, in some cases to help establish a diagnosis and plan treatment.

Subjects

MeSH terms (MEDLINE)

Ampulla of VaterAnimalsCatsReference ValuesUltrasonographyMaleFemaleProspective StudiesCase-Control StudiesDuodenum

Authors and institutions

  • Tierklinik Düsseldorf GmbH, Düsseldorf, Germany.

ORCID profiles: R Leppin

Cite

APA

Leppin, R. (2025). Detection frequency, sonoanatomy and reference values of the duodenal papillae and connected anatomical structures in cats. Journal of Small Animal Practice. https://doi.org/10.1111/jsap.13813

Vancouver

Leppin R. Detection frequency, sonoanatomy and reference values of the duodenal papillae and connected anatomical structures in cats. Journal of Small Animal Practice. 2025. doi:10.1111/jsap.13813

BibTeX
@article{Leppin2025,
  author = {Leppin, R},
  title = {Detection frequency, sonoanatomy and reference values of the duodenal papillae and connected anatomical structures in cats},
  journal = {Journal of Small Animal Practice},
  year = {2025},
  doi = {10.1111/jsap.13813}
}
Start for free →