Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates

Sourabh Dutta, Arnab Pal, Pallab Ray

Journal of Paediatrics and Child Health · 2025

DOI: 10.1111/jpc.70217 ↗

At a glance

Journal article in Journal of Paediatrics and Child Health, 2025. Written by Sourabh Dutta and 2 co-authors. Institution: Department of Pediatrics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. Major MEDLINE topics: Leukocytosis, Carboxylic Ester Hydrolases. 24 references. Funded by: Department of Biotechnology, Ministry of Science and Technology, India.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objectives

The study evaluated neonatal cerebro‐spinal fluid (CSF) leucocyte esterase (LE) estimation by reagent strips to diagnose CSF leucocytosis in situations where the CSF leucocyte count is delayed or unavailable.

Methods

This prospective diagnostic study had a cohort‐selection design. CSF samples of neonates with clinical sepsis were analysed for LE by reagent strips, cytochemistry, gram stain and culture. CSF LE was measured on an ordinal scale from nil to large. Correlations of CSF LE with CSF leucocyte and neutrophil count were determined. CSF LE was compared versus CSF leucocytosis (defined a priori ≥ 25 leucocytes/μL) and versus CSF neutrophilia (defined a priori ≥ 15 neutrophils/μL) as the reference standard.

Results

A total of 341 neonates were enrolled. CSF LE values correlated with leucocyte count (rho = 0.49, p < 0.001) and neutrophil count (rho = 0.44, p < 0.001). LE had a sensitivity (95% CI) of 63.5% (51.2, 74.1), specificity 90.7% (88.4, 92.6), LR+ (likelihood ratio) 6.79 (4.43, 9.98) and LR− 0.40 (0.28, 0.55) to diagnose CSF leucocytosis. When expressed as an ordinal variable, LE had an area under the receiver operator characteristic curve of 0.77 (95% CI: 0.69, 0.85; p < 0.001) to detect leucocytosis. With respect to all parameters, the diagnostic performance of CSF LE to detect neutrophilia was inferior to the detection of leucocytosis.

Conclusions

CSF leucocyte esterase estimation by reagent strips has a moderately high specificity and a good LR + but, overall, does not have sufficiently robust diagnostic accuracy to substitute CSF leucocyte counts.

Subjects

MeSH terms (MEDLINE)

LeukocytosisCarboxylic Ester HydrolasesHumansInfant, NewbornProspective StudiesMaleFemaleLeukocyte CountSensitivity and Specificity

Author keywords

cerebrospinal fluidleucocyte esteraseneonatepleocytosis

Substances

leukocyte esteraseCarboxylic Ester Hydrolases

Authors and institutions

  • Department of Pediatrics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Biochemistry, PGIMER, Chandigarh, India.
  • Department of Medical Microbiology, PGIMER, Chandigarh, India.

Funding

  • Department of Biotechnology, Ministry of Science and Technology, India

Cite

APA

Dutta, S., Pal, A., & Ray, P. (2025). Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates. Journal of Paediatrics and Child Health. https://doi.org/10.1111/jpc.70217

Vancouver

Dutta S, Pal A, Ray P. Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates. Journal of Paediatrics and Child Health. 2025. doi:10.1111/jpc.70217

BibTeX
@article{Dutta2025,
  author = {Dutta, Sourabh and Pal, Arnab and Ray, Pallab},
  title = {Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates},
  journal = {Journal of Paediatrics and Child Health},
  year = {2025},
  doi = {10.1111/jpc.70217}
}
Start for free →