Fachartikel in der Zeitschrift Journal of Paediatrics and Child Health, 2025. Verfasst von Sourabh Dutta und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. Hauptthemen laut MEDLINE: Leukocytosis, Carboxylic Ester Hydrolases. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Department of Biotechnology, Ministry of Science and Technology, India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The study evaluated neonatal cerebro‐spinal fluid (CSF) leucocyte esterase (LE) estimation by reagent strips to diagnose CSF leucocytosis in situations where the CSF leucocyte count is delayed or unavailable.

Methods

This prospective diagnostic study had a cohort‐selection design. CSF samples of neonates with clinical sepsis were analysed for LE by reagent strips, cytochemistry, gram stain and culture. CSF LE was measured on an ordinal scale from nil to large. Correlations of CSF LE with CSF leucocyte and neutrophil count were determined. CSF LE was compared versus CSF leucocytosis (defined a priori ≥ 25 leucocytes/μL) and versus CSF neutrophilia (defined a priori ≥ 15 neutrophils/μL) as the reference standard.

Results

A total of 341 neonates were enrolled. CSF LE values correlated with leucocyte count (rho = 0.49, p < 0.001) and neutrophil count (rho = 0.44, p < 0.001). LE had a sensitivity (95% CI) of 63.5% (51.2, 74.1), specificity 90.7% (88.4, 92.6), LR+ (likelihood ratio) 6.79 (4.43, 9.98) and LR− 0.40 (0.28, 0.55) to diagnose CSF leucocytosis. When expressed as an ordinal variable, LE had an area under the receiver operator characteristic curve of 0.77 (95% CI: 0.69, 0.85; p < 0.001) to detect leucocytosis. With respect to all parameters, the diagnostic performance of CSF LE to detect neutrophilia was inferior to the detection of leucocytosis.

Conclusions

CSF leucocyte esterase estimation by reagent strips has a moderately high specificity and a good LR + but, overall, does not have sufficiently robust diagnostic accuracy to substitute CSF leucocyte counts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeukocytosisCarboxylic Ester HydrolasesHumansInfant, NewbornProspective StudiesMaleFemaleLeukocyte CountSensitivity and Specificity

Stichwörter der Autor:innen

cerebrospinal fluidleucocyte esteraseneonatepleocytosis

Substanzen

leukocyte esteraseCarboxylic Ester Hydrolases

Autor:innen und Institutionen

  • Department of Pediatrics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Biochemistry, PGIMER, Chandigarh, India.
  • Department of Medical Microbiology, PGIMER, Chandigarh, India.

Förderung

  • Department of Biotechnology, Ministry of Science and Technology, India

Zitieren

APA

Dutta, S., Pal, A., & Ray, P. (2025). Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates. Journal of Paediatrics and Child Health. https://doi.org/10.1111/jpc.70217

Vancouver

Dutta S, Pal A, Ray P. Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates. Journal of Paediatrics and Child Health. 2025. doi:10.1111/jpc.70217

BibTeX
@article{Dutta2025,
  author = {Dutta, Sourabh and Pal, Arnab and Ray, Pallab},
  title = {Leukocyte Esterase Estimation to Diagnose Cerebro‐Spinal Fluid Leucocytosis in Neonates},
  journal = {Journal of Paediatrics and Child Health},
  year = {2025},
  doi = {10.1111/jpc.70217}
}
Kostenlos starten →