EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting

Sang-Ah Lee iD, Kyung-Ho Ko iD, Yoon-Hyuk Huh iD, Chan-Jin Park iD, Lee-Ra Cho iD

Journal of Prosthodontics · 21.08.2026

DOI: 10.1111/jopr.70220 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 21.08.2026. Verfasst von Sang-Ah Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Kangwon National University, Gangneung, Republic of Korea. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Regional Innovation System & Education (RISE) Glocal University 30 Project Program, funded by the Ministry of Education (MOE) and the Gangwon State (G.S.), Rep….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the fracture resistance of implant‐supported metal–ceramic crowns fabricated using selective laser melting (SLM), according to the metal support height around the screw access hole (SAH) and the substructure design. Materials and Methods Metal–ceramic crowns and rectangular bilayer specimens were fabricated using SLM in two independent experimental series. In the SAH design series, the substructure design was kept constant while the metal support height around the SAH was varied (none, half, and complete metal support; n = 12 per group). In the substructure design series, the SAH configuration was held constant (complete metal support), and the metal substructure design was varied (uniform cut‐back, lingual support, and circumferential ring support; n = 12 per group). Crown specimens underwent thermomechanical aging (50 N, 100,000 cycles, 2 Hz, 5°C–55°C), followed by fracture resistance testing, Weibull analysis, failure mode classification, and fractographic analysis. Rectangular bilayer specimens representing each framework design were used for edge‐chipping evaluation. Statistical analyses used one‐way ANOVA and Tukey HSD tests (α = 0.05).

Results

The complete metal support SAH design showed significantly greater fracture resistance than the other SAH configurations ( p < 0.05). However, in the corresponding rectangular bilayer specimens, this design showed the lowest edge‐chipping resistance among the SAH configurations. Fractographic analysis showed that fractures originated at the occlusal loading site and propagated toward the crown margin. Among substructure designs, the circumferential ring design exhibited significantly greater fracture resistance and superior edge‐chipping resistance compared with other designs ( p < 0.05).

Conclusions

Complete metal support around the SAH improved fracture resistance. Loading close to the SAH may increase susceptibility to veneering ceramic chipping under the tested conditions. A circumferential ring design providing uniform ceramic support enhanced overall mechanical performance.

Schlagwörter

Stichwörter der Autor:innen

fracture resistancemetal‐ceramic crownprosthesis designscrew access holeselective laser melting

Autor:innen und Institutionen

  • Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Kangwon National University, Gangneung, Republic of Korea.

ORCID-Profile: Sang-Ah Lee, Kyung-Ho Ko, Yoon-Hyuk Huh, Chan-Jin Park, Lee-Ra Cho

Förderung

  • Regional Innovation System & Education (RISE) Glocal University 30 Project Program, funded by the Ministry of Education (MOE) and the Gangwon State (G.S.), Rep…

Zitieren

APA

Lee, S. A., Ko, K. H., Huh, Y. H., Park, C. J., & Cho, L. R. (2026). Effect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70220

Vancouver

Lee SA, Ko KH, Huh YH, Park CJ, Cho LR. Effect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70220

BibTeX
@article{Lee2026,
  author = {Lee, Sang-Ah and Ko, Kyung-Ho and Huh, Yoon-Hyuk and Park, Chan-Jin and Cho, Lee-Ra},
  title = {Effect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting},
  journal = {Journal of Prosthodontics},
  year = {2026},
  doi = {10.1111/jopr.70220}
}
Kostenlos starten →