Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 17.03.2025. Verfasst von Lucio Lo Russo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Surgical guides are medical devices used in static implant surgery to replicate the prosthetic and surgical implant position planned with computer‐assisted software before surgery. Their use reduces invasiveness and improves safety and outcomes of implant surgery, provided that their accuracy is ensured from design to manufacturing and then to clinical usage. One of the factors that may potentially interfere with their accuracy is the sterilization procedure. The present study aimed to analyze how autoclave sterilization affects 3D‐printed surgical guide stability. Materials and Methods Ten 3D‐printed surgical guides were scanned before (T0) and after (T1) autoclave sterilization. T0 and T1 scans were compared with the corresponding CAD model in a surface matching software program. Trueness of the intaglio surface, linear and axial deviations of sleeves’ housings at T0 and T1 were measured and statistically analyzed by generalized estimated equation (GEE) models to evaluate the effects of the sterilization procedure.

Results

Surface variations, linear and axial deviations of sleeves’ housings were found to be significantly ( p < 0.05) affected by the sterilization only in combination with the volume or the total surface area of the surgical guides. The magnitude of the T0‐T1 differences was small (0.016 mm and 0.035 mm for mean absolute deviation (MAD) at the intaglio surface in contact with teeth or mucosa; 0.009 mm for linear deviation of the central point of sleeves’ housings; 0.084° and 0.180° for their axial deviation on the sagittal and frontal planes).

Conclusion

The effects of autoclave sterilization on the stability of 3D‐printed surgical guides remain limited and clinically insignificant.

Schlagwörter

Stichwörter der Autor:innen

accuracyautoclave sterilizationdimensional stabilitysurgical guides

Autor:innen und Institutionen

  • Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy.
  • Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy.
  • Departments of Prosthodontics and Periodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.
  • Department of Prosthodontics & Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.

ORCID-Profile: Lucio Lo Russo, Carlo Ercoli, Fariba Esperouz

Zitieren

APA

Lo Russo, L., Mariani, P., Ercoli, C., Caprio, G., Park, J. M., Laino, L., & Esperouz, F. (2025). Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis. Journal of Prosthodontics. https://doi.org/10.1111/jopr.14049

Vancouver

Lo Russo L, Mariani P, Ercoli C, Caprio G, Park JM, Laino L, et al. Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis. Journal of Prosthodontics. 2025. doi:10.1111/jopr.14049

BibTeX
@article{LoRusso2025,
  author = {Lo Russo, Lucio and Mariani, Pierluigi and Ercoli, Carlo and Caprio, Giusy and Park, Ji-Man and Laino, Luigi and Esperouz, Fariba},
  title = {Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.14049}
}
Kostenlos starten →