Three Dimensional Printed Surgical Guides: Effect of Time on Dimensional Stability
Journal of Prosthodontics · 2023-06 · 32 (5) · 431-438
DOI: 10.1111/jopr.13573 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 10.08.2022. Verfasst von Lucio Lo Russo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy. Hauptthemen laut MEDLINE: Computer-Aided Design, Surgery, Computer-Assisted. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Purpose
To analyze, in vitro, the dimensional stability over time of 3D‐printed surgical guides. Materials and methods Ten surgical guides, manufactured by digital light processing 3D‐printing technology, were scanned immediately after post‐processing and then after 5, 10, 15, and 20 days. The corresponding standard tessellation language (STL) files were used for comparison with the reference CAD project. Mean absolute deviation (MAD) of the intaglio surface, axial, and linear deviations of the sleeves’ housings were measured. Generalized estimated equations models (α = 0.05) were used to investigate the effect of time.
Results
MAD of the teeth intaglio surface showed less variation (minimum: 0.002, maximum: 0.014 mm) than that of the mucosa (minimum: 0.026, maximum: 0.074 mm). Axial variations of the sleeves’ housings on the sagittal (minimum: –0.008°, maximum: –0.577°) and frontal plane (minimum: –0.193°, maximum: 0.525°) changed with similar patterns, but opposite trends (decreasing for the former). Linear deviations of center points of the sleeves’ housings had a shifting (minimum: –0.074, maximum: 0.02 mm) pattern with a decreasing tendency. Time after processing had a significant effect, either alone or nested with guides volume, on all outcomes of interest, except for MAD of the mucosa intaglio surface ( p < 0.001), which was significantly affected only by the time‐volume nested effect ( p = 0.012).
Conclusions
Within the limitations of the experimental design, postmanufacturing dimensional variations of surgical guides were statistically significant. Although limited, they are an additional source of variability affecting the overall accuracy of computer‐guided surgery. As such, they should be addressed by further research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy.
- Private practice, Salus Oris srl, Vallesaccarda (AV), Italy.
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York.
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania, "Luigi Vanvitelli", Naples, Italy.
ORCID-Profile: Lucio Lo Russo, Carlo Ercoli
Zitieren
APA
Lo Russo, L., Guida, L., Zhurakivska, K., Troiano, G., Di Gioia, C., Ercoli, C., & Laino, L. (2023). Three Dimensional Printed Surgical Guides: Effect of Time on Dimensional Stability. Journal of Prosthodontics, 32(5), 431-438. https://doi.org/10.1111/jopr.13573
Vancouver
Lo Russo L, Guida L, Zhurakivska K, Troiano G, Di Gioia C, Ercoli C, et al. Three Dimensional Printed Surgical Guides: Effect of Time on Dimensional Stability. Journal of Prosthodontics. 2023;32(5):431-438. doi:10.1111/jopr.13573
BibTeX
@article{LoRusso2023,
author = {Lo Russo, Lucio and Guida, Laura and Zhurakivska, Khrystyna and Troiano, Giuseppe and Di Gioia, Claudio and Ercoli, Carlo and Laino, Luigi},
title = {Three Dimensional Printed Surgical Guides: Effect of Time on Dimensional Stability},
journal = {Journal of Prosthodontics},
year = {2023},
volume = {32},
number = {5},
pages = {431--438},
doi = {10.1111/jopr.13573}
}
EUVIMED