Augmented‐reality‐assisted intraoral scanning: A proof‐of‐concept study
Journal of Prosthodontics · 2024
DOI: 10.1111/jopr.13836 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Seung Jun Song und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Prosthodontics, Columbia University College of Dental Medicine, New York, USA. Hauptthemen laut MEDLINE: Proof of Concept Study, Augmented Reality. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
Purpose
The aims of the present study were (a) to compare the scanning time and image count to complete optical scans of a typodont between augmented‐reality‐assisted intraoral scanning (ARIOS) and intraoral scanning (IOS); (b) to compare the accuracy of the digital casts derived from ARIOS and IOS; (c) to compare participant‐related outcomes between ARIOS and IOS. Materials and Methods A multi‐session within‐subject experiment was conducted to compare ARIOS and IOS. Thirty‐one dental students participated in the study. Following a trial session, each participant obtained optical scans under ARIOS and IOS conditions. The time required to complete the scan, and the number of images taken were recorded. Participant feedback was collected using entry, exit, and NASA‐Task Load Index (TLX) surveys. The accuracy of the digital casts derived from the optical scans was measured in root mean square error (RMSE).
Results
The present study found a 6.8% increase in preference for ARIOS from entry to exit survey. Slightly more participants favored the ARIOS setup compared to IOS; 54.8% of participants favored ARIOS, 9.7% were indifferent, and 35.5% favored IOS. NASA‐TLX subscale ratings were higher for IOS in general apart from mental demand. The accuracy of the digital casts between ARIOS and IOS was comparable in RMSE.
Conclusion
ARIOS was advantageous compared to IOS in ergonomics, improved scanner tracking, and ease of scanner orientation. However additional trials, increased field of view, and better superimposition of scanning status to the target site were improvements desired by the study participants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Prosthodontics, Columbia University College of Dental Medicine, New York, USA.
- Columbia University College of Dental Medicine, New York, USA.
- Division of Fixed Prosthodontics and Biomaterials, University of Geneva, University Clinics for Dental Medicine, Geneva, Switzerland.
- Computer Science, Columbia University School of Engineering and Applied Science, New York, USA.
ORCID-Profile: Seung Jun Song
Zitieren
APA
Song, S. J., Tang, M., Gwartzman, B., Lee, D., Romandini, P., Salem, M., Kwon, P., Feiner, S. K., & Sailer, I. (2024). Augmented‐reality‐assisted intraoral scanning: A proof‐of‐concept study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13836
Vancouver
Song SJ, Tang M, Gwartzman B, Lee D, Romandini P, Salem M, et al. Augmented‐reality‐assisted intraoral scanning: A proof‐of‐concept study. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13836
BibTeX
@article{Song2024,
author = {Song, Seung Jun and Tang, Madison and Gwartzman, Brynn and Lee, Derek and Romandini, Pierluigi and Salem, Maurice and Kwon, Patrick and Feiner, Steven K and Sailer, Irena},
title = {Augmented‐reality‐assisted intraoral scanning: A proof‐of‐concept study},
journal = {Journal of Prosthodontics},
year = {2024},
doi = {10.1111/jopr.13836}
}
EUVIMED