EUVIMEDEUVIMED entdecken
Crossref

Three-dimensional assessment of virtual clear aligner attachment removal: A prospective clinical study

Jeremy Dock, Flavio Copello, Iman Shirmohammadi, Jose A Bosio

American Journal of Orthodontics and Dentofacial Orthopedics · 2024

DOI: 10.1016/j.ajodo.2024.02.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2024. Verfasst von Jeremy Dock und 3 weiteren Autor:innen. Beteiligte Einrichtung: Formerly, Division of Orthodontics, Department of Orthodontics and Pediatric Dentistry, University of Maryland School of Dentistry, Baltimore, Md; Cu…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: In digital dentistry, virtual attachment removal (VAR) optimizes clear aligner therapy by enhancing efficiency for refinements and enabling prefabricated retainer production through the removal of attachments from a digital scan before the clinical removal of clear aligner attachments. This prospective clinical study aimed to evaluate the accuracy of VAR in the maxillary arch. METHODS: A total of 110 teeth were analyzed from a sample of 54 maxillary scans from 25 subjects. Models with attachments were virtually debonded using Meshmixer (Autodesk, San Rafael, Calif) and superimposed over the control group in MeshLab. Vector Analysis Module (Canfield Scientific, Fairfield, NJ) was used to calculate and analyze 3-dimensional Euclidean distances on the buccal surfaces between the superimposed models. Statistical analysis was performed using SPSS (version 23.0, IBM, Armonk, NY). The Shapiro-Wilkes (α = 0.05) test determined a nonnormal distribution of results. The Kruskal-Wallis (α = 0.05) was used to determine differences between different tooth types and the number of attachments. RESULTS: The VAR protocol showed no statistical differences in the root mean square between different tooth segments with an overall tendency for inadequate attachment removal. No difference between the groups was found regarding the number of attachments when used as a main factor. CONCLUSIONS: The VAR technique is precise enough for the fabrication of retainers from printed dental models in a clinical setting and is not affected by the number of attachments on the tooth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalHumansProspective StudiesFemaleMaleMaxillaYoung AdultOrthodontic Appliance DesignTooth Movement TechniquesAdultAdolescentOrthodontic RetainersModels, DentalComputer-Aided Design

Autor:innen und Institutionen

  • Formerly, Division of Orthodontics, Department of Orthodontics and Pediatric Dentistry, University of Maryland School of Dentistry, Baltimore, Md; Currently, Private practice, Cincinnati, Ohio. Electronic address: jerem…
  • Division of Orthodontics, Department of Orthodontics and Pediatric Dentistry, University of Maryland School of Dentistry, Baltimore, Md.

Zitieren

APA

Dock, J., Copello, F., Shirmohammadi, I., & Bosio, J. A. (2024). Three-dimensional assessment of virtual clear aligner attachment removal: A prospective clinical study. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2024.02.006

Vancouver

Dock J, Copello F, Shirmohammadi I, Bosio JA. Three-dimensional assessment of virtual clear aligner attachment removal: A prospective clinical study. American Journal of Orthodontics and Dentofacial Orthopedics. 2024. doi:10.1016/j.ajodo.2024.02.006

BibTeX
@article{Dock2024,
  author = {Dock, Jeremy and Copello, Flavio and Shirmohammadi, Iman and Bosio, Jose A},
  title = {Three-dimensional assessment of virtual clear aligner attachment removal: A prospective clinical study},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2024},
  doi = {10.1016/j.ajodo.2024.02.006}
}
Kostenlos starten →