Shear bond strength characteristics on surface treatment modalities of CAD‐CAM resin polymers

Nikita Sinha iD, Geoffrey A Thompson iD, Carl Drago iD, Hongseok An iD

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.13790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Nikita Sinha und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Creighton University School of Dentistry, Omaha, Nebraska, USA. Hauptthemen laut MEDLINE: Composite Resins, Computer-Aided Design, Dental Bonding, Polymers. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high‐performance polymer material for fixed, screw‐retained full arch restorations. Material and Methods A total of 135 computer‐aided design and computer‐aided manufacturing, high‐performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica‐modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil‐free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples. The manufacturer's recommendations were followed for bonding composite resin to the samples with light‐cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty‐seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled. Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated. Statistical analysis was performed with post‐hoc Tukey tests.

Results

Statistical analysis revealed that there was a significant difference between the groups ( p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Composite ResinsComputer-Aided DesignDental BondingPolymersDental MaterialsShear StrengthSurface PropertiesMaterials TestingAluminum OxideIn Vitro TechniquesHumansDental Stress AnalysisDental Cements

Stichwörter der Autor:innen

PEEKPEKKTONTRILORbond strengthhigh‐performance polymers

Substanzen

Composite ResinsPolymersDental MaterialsAluminum OxideRocatecDental Cements

Autor:innen und Institutionen

  • Department of Prosthodontics, Creighton University School of Dentistry, Omaha, Nebraska, USA.
  • Department of Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin, USA.
  • Department of Restorative Dentistry, Graduate Prosthodontics OHSU, Portland, Oregon, USA.

ORCID-Profile: Nikita Sinha, Geoffrey A Thompson, Carl Drago, Hongseok An

Zitieren

APA

Sinha, N., Thompson, G. A., Drago, C., & An, H. (2025). Shear bond strength characteristics on surface treatment modalities of CAD‐CAM resin polymers. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13790

Vancouver

Sinha N, Thompson GA, Drago C, An H. Shear bond strength characteristics on surface treatment modalities of CAD‐CAM resin polymers. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13790

BibTeX
@article{Sinha2025,
  author = {Sinha, Nikita and Thompson, Geoffrey A and Drago, Carl and An, Hongseok},
  title = {Shear bond strength characteristics on surface treatment modalities of CAD‐CAM resin polymers},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.13790}
}
Kostenlos starten →