EUVIMEDEUVIMED entdecken
Crossref

Assessment of tooth positions of printed complete dentures with different designs and tooth positioning techniques

Yasmine Galaleldin Thabet iD, Marwa Ezzat Sabet, Muhammad Amr Nabil, Tarek Mohamed Al Sayed El Saaedi iD, Hebatallah Tarek Mohamed

Journal of Prosthodontics · 2024-10 · 33 (8) · 808-814

DOI: 10.1111/jopr.13769 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 03.10.2023. Verfasst von Yasmine Galaleldin Thabet und 4 weiteren Autor:innen. Beteiligte Einrichtung: Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. Hauptthemen laut MEDLINE: Denture, Complete, Denture Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the accuracy of tooth positions in printed complete dentures with different designs and teeth positioning techniques. Materials and Methods Five different designs of complete dentures and teeth positioning techniques were evaluated in this in vitro study. In Group I, the denture bases and teeth were designed as a single piece. In groups II and III, the denture bases were designed separately, and the denture teeth were designed as separate teeth. In groups IV and V, the denture bases were designed separately, and the denture teeth were designed as a single piece. Teeth positioning keys were designed for groups III and V. The dentures of all groups were scanned, and the data were imported to the surface matching software to evaluate the accuracy of the teeth positions. Statistical analysis was done using One ‐way ANOVA of Variance. The significance level was set at p ≤ 0.05.

Results

The results showed that the highest deviations of the positions of the canines (0.0781 ± 0.0154 mm) and the first molars (0.0611 ± 0.0055 mm) were found in Group II. On the other hand, Group I showed the least deviations of the positions of the canines (0.0287 ± 0.0054 mm) and molars (0.0354 ± 0.005 mm).

Conclusions

The most accurate tooth positions are obtained in monolithic printed complete dentures. Fewer deviations in tooth positions occur when denture teeth are designed as a single piece.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, CompleteDenture DesignHumansDenture BasesTooth, ArtificialComputer-Aided DesignIn Vitro Techniques

Stichwörter der Autor:innen

accuracypositioning keyprinted denturestooth deviations

Autor:innen und Institutionen

  • Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

ORCID-Profile: Yasmine Galaleldin Thabet, Tarek Mohamed Al Sayed El Saaedi

Zitieren

APA

Thabet, Y. G., Sabet, M. E., Nabil, M. A., El Saaedi, T. M. A. S., & Mohamed, H. T. (2024). Assessment of tooth positions of printed complete dentures with different designs and tooth positioning techniques. Journal of Prosthodontics, 33(8), 808-814. https://doi.org/10.1111/jopr.13769

Vancouver

Thabet YG, Sabet ME, Nabil MA, El Saaedi TMAS, Mohamed HT. Assessment of tooth positions of printed complete dentures with different designs and tooth positioning techniques. Journal of Prosthodontics. 2024;33(8):808-814. doi:10.1111/jopr.13769

BibTeX
@article{Thabet2024,
  author = {Thabet, Yasmine Galaleldin and Sabet, Marwa Ezzat and Nabil, Muhammad Amr and El Saaedi, Tarek Mohamed Al Sayed and Mohamed, Hebatallah Tarek},
  title = {Assessment of tooth positions of printed complete dentures with different designs and tooth positioning techniques},
  journal = {Journal of Prosthodontics},
  year = {2024},
  volume = {33},
  number = {8},
  pages = {808--814},
  doi = {10.1111/jopr.13769}
}
Kostenlos starten →