Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study
The Journal of Prosthetic Dentistry · 2024
DOI: 10.1016/j.prosdent.2024.01.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Akram F Neena und 1 weiteren Autor:innen. Beteiligte Einrichtung: Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt. Electronic address: akram.morshedy@alexu.e…. Hauptthemen laut MEDLINE: Tooth, Artificial, Denture Bases. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) removable dentures have become popular. However, evaluations of the effect of denture base-tooth offset (DTO) values on the trueness of artificial teeth are lacking. PURPOSE: The purpose of this in vitro study was to digitally measure the trueness of the artificial teeth of CAD-CAM dentures fabricated with additive manufacturing using different DTO values and to determine the most accurate DTO value. MATERIAL AND METHODS: Seven study groups were formulated based on different DTO values, and 6 maxillary complete dentures were assigned to each group (n=42). A design software program was used to export the monoblock denture as control, the artificial teeth, and 7 different designs of denture bases with DTO values of 0.00, 0.01, 0.03, 0.05, 0.10, 0.15, and 0.20 mm. Denture bases were printed in denture base resin (Denture base RP; formlabs), artificial teeth were printed in tooth-shade resin (Denture teeth A2; formlabs), and both were then assembled and polymerized together. The dentures were scanned (InEos X5; Dentsply Sirona), scan data were imported in a measuring software program (GOM Inspect; GOM GmbH), and registration using local best fit was performed to align data. Color-coded maps for the surface comparison of each denture with the control denture scan were generated. Fitting center points were constructed for each artificial tooth, which were compared with their corresponding points on the data of the control scan. Multiple pairwise comparisons were performed after 1-way ANOVA to quantify and statistically evaluate the deviation values (α=.05). RESULTS: The 0.10-mm DTO group showed the lowest values when comparing artificial tooth deviations both individually and as types. On comparing the average deviations, statistically significant differences were identified among the 7 groups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt. Electronic address: akram.morshedy@alexu.edu.eg.
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt.
Zitieren
APA
Neena, A. F., & Abd-Ellah, M. E. (2024). Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.01.001
Vancouver
Neena AF, Abd-Ellah ME. Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.01.001
BibTeX
@article{Neena2024,
author = {Neena, Akram F and Abd-Ellah, Mervat E},
title = {Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
doi = {10.1016/j.prosdent.2024.01.001}
}
EUVIMED