EUVIMEDEUVIMED entdecken
Klinische StudieOpen Access · CC BY-NC-ND 4.0

Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years

Oliver Schubert iD, Janosch Goob, Josef Schweiger, Jan-Frederik Güth iD, Daniel Edelhoff, Tobias Graf iD

Journal of Prosthodontics · 2024

DOI: 10.1111/jopr.13719 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Oliver Schubert und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Dental Porcelain, Titanium. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Hybrid abutment crowns (HACs) made from monolithic ceramics represent an efficient option for single restorations on implants. However, long‐term data are scarce. The purpose of this clinical trial was to evaluate the survival and complication rates of CAD‐CAM fabricated HACs over a time period of at least 3.5 years. Materials and Methods Twenty‐five patients with a total of 40 HACs made of monolithic lithium disilicate ceramic bonded to a titanium base CAD‐CAM abutment were retrospectively evaluated. All implants and screw‐retained restorations were placed and manufactured in the same department of a university hospital. Only crowns that had been in service for more than 3.5 years were included in the study. HACs were evaluated regarding technical and biological complications. Functional Implant Prosthodontic Scores (FIPS) were obtained.

Results

The mean observation time was 5.9 ± 1.4 years. Implant survival was 100%, and HAC survival was 97.5%. Over the observation period, one crown fracture was observed, necessitating refabricating of the restoration. Three minor biological complications were found. The overall mean FIPS score was 8.69 ± 1.12 points.

Conclusions

Within the limitations of this study, monolithic screw‐retained HACs milled from lithium disilicate ceramics and bonded to titanium bases appeared to be a reliable treatment option over more than 3.5 years due to their low biological and technical complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental PorcelainTitaniumHumansCeramicsComputer-Aided DesignCrownsDental Restoration FailureMaterials TestingRetrospective Studies

Stichwörter der Autor:innen

CAD-CAMcomplicationsdental implanthybrid abutment crownslithium disilicatemonolithic restorations

Substanzen

Dental Porcelainlithia disilicateTitanium

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.
  • Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.

ORCID-Profile: Oliver Schubert, Jan-Frederik Güth, Tobias Graf

Zitieren

APA

Schubert, O., Goob, J., Schweiger, J., Güth, J. F., Edelhoff, D., & Graf, T. (2024). Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13719

Vancouver

Schubert O, Goob J, Schweiger J, Güth JF, Edelhoff D, Graf T. Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13719

BibTeX
@article{Schubert2024,
  author = {Schubert, Oliver and Goob, Janosch and Schweiger, Josef and Güth, Jan-Frederik and Edelhoff, Daniel and Graf, Tobias},
  title = {Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years},
  journal = {Journal of Prosthodontics},
  year = {2024},
  doi = {10.1111/jopr.13719}
}
Kostenlos starten →