Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners
Journal of Prosthodontics · 2024
DOI: 10.1111/jopr.13686 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Ashraf Yehia und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Impression Technique. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 54 Literaturangaben.
Abstract (Originalsprache)
Purpose
The aim was to assess the effect of span lengths and total occlusal convergence (TOC) on the accuracy of intraoral scanners . Materials and methods Two typodont acrylic teeth models were prepared to receive fixed dental prostheses with three different span lengths. Span 1: between maxillary canines; span 2: between maxillary second premolars; and span 3: between maxillary second molars. In the first model, prepared teeth had a TOC of 12°, whereas, in the second model, teeth had a TOC of 20°. Each model was scanned 10 times using 4 different intraoral scanners (Omnicam, Primescan, Trios 4, and Medit i500). The STL files from the scans were compared to the reference models (trueness) and within each test group (precision) using a 3D comparison software. Data were then statistically analyzed.
Results
Regarding trueness, no significant differences were found among Primescan (32.58 ± 13.08), Trios 4 (32.33 ± 12.19), and Medit i500 (32.26 ± 9.57). However, all showed significantly better trueness than Omnicam (35.70 ± 8.35) ( p < 0.001). The highest values were found in scans between the second molars (47.42 ± 3.94), followed by scans between second premolars (28.42 ± 3.78), and the highest trueness was found in scans between the canines (23.80 ± 3.85). For TOC, 12° had a significantly higher value than 20° ( p < 0.001). Regarding precision, the highest values were found with Omnicam (29.84 ± 3.89), followed by Medit i500 (28.04 ± 2.94), then Trios 4 (25.64 ± 3.11), and Primescan (24.69 ± 5.25). The highest values and least precision were found in scans between the second molars (28.97 ± 5.27) and scans between second premolars (27.59 ± 3.97), whereas the highest precision was found in scans between the canines (24.60 ± 2.04). For TOC, 12° had significantly higher values than 20° ( p < 0.001).
Conclusions
Intraoral scans are directly affected by scanner type, TOC, and scan spans. All tested scanners showed clinically acceptable results even for long‐span restorations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
- Department of Fixed Prosthodontics, Faculty of Dentistry, British University in Egypt, Cairo, Egypt.
ORCID-Profile: Kamal Ebeid
Zitieren
APA
Yehia, A., Abo El Fadl, A., El Sergany, O., & Ebeid, K. (2024). Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13686
Vancouver
Yehia A, Abo El Fadl A, El Sergany O, Ebeid K. Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13686
BibTeX
@article{Yehia2024,
author = {Yehia, Ashraf and Abo El Fadl, Ahmad and El Sergany, Omar and Ebeid, Kamal},
title = {Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners},
journal = {Journal of Prosthodontics},
year = {2024},
doi = {10.1111/jopr.13686}
}
EUVIMED