Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD‐CAM systems: A prospective clinical study
Journal of Prosthodontics · 2023
DOI: 10.1111/jopr.13675 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, 2023. Verfasst von Alejandro Sanchez-Lara und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA. Hauptthemen laut MEDLINE: Dental Porcelain, Crowns. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Purpose
This prospective clinical study evaluated and compared the marginal and internal fit of crowns fabricated with an analog workflow and three different computer‐aided design and computer‐aided manufacturing (CAD–CAM) systems. Materials and methods Twenty‐five participants in need of a single complete‐coverage molar or premolar crown were recruited in the study. Twenty‐two completed the study, and three participants dropped out. Teeth were prepared according to a standardized protocol by one operator. For each participant, one final impression was made with polyether material (PP) and three intraoral scanners: CEREC Omnicam (C), Planmeca Planscan (PM), and True Definition (TR). For the PP group, crowns were fabricated with a pressable lithium disilicate ceramic, whereas for the other three groups (C, PM, and TR), crowns were designed and milled with dedicated CAD–CAM systems and materials. Marginal (vertical and horizontal) and internal discrepancies between the crowns and tooth preparation were measured at various locations with digital superimposition software. Data was analyzed for normality with Kolmogorov–Smirnov and Shapiro–Wilk tests and then compared with one‐way ANOVA and Kruskal–Wallis tests.
Results
Mean vertical marginal gap values were 92.18 ± 141.41 μm (PP), 150.12 ± 138.06 μm (C), 129.07 ± 109.96 μm (PM), and 135.09 ± 112.03 μm (TR). PP group had statistically significantly smaller vertical marginal discrepancy ( p = 0.001) than all other groups, whereas no significant difference was detected among the three CAD–CAM systems (C, PM, and TR). Horizontal marginal discrepancies were 104.93 ± 111.96 μm (PP), 89.49 ± 119.66 μm (C), 113.36 ± 128.49 μm (PM), and 136.39 ± 142.52 μm (TR). A significant difference was detected only between C and TR ( p < 0.0001). Values for the internal fit were 128.40 ± 49.31μm (PP), 190.70 ± 69.79μm (C), 146.30 ± 57.70 μm (PM), and 168.20 ± 86.67 μm (TR). The PP group had a statistically significant smaller internal discrepancy than C ( p < 0.0001) and TR groups ( p = 0.001), whereas no significant difference was found compared to the PM group.
Conclusion
Posterior crowns fabricated with CAD–CAM systems showed vertical margin discrepancy greater than 120 μm. Only crowns fabricated with the conventional methodology had vertical margins below 100 μm. Horizontal marginal discrepancy was different among all groups, and only CEREC CAD–CAM was below 100 μm. Internal discrepancy was less for crowns fabricated with an analog workflow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.
- Department of Restorative Dental Sciences, Division of Prosthodontics, University of Florida College of Dentistry, Gainesville, Florida, USA.
- Private practice, Dubai, United Arab Emirates.
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania, USA.
- Division of Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
- Departments of Prosthodontics and Periodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.
ORCID-Profile: Sherif Hosney, Evangelina Lampraki, Carlo Ercoli, Konstantinos Chochlidakis
Zitieren
APA
Sanchez-Lara, A., Hosney, S., Lampraki, E., Conejo, J., Blatz, M. B., Barmak, A. B., Ercoli, C., & Chochlidakis, K. (2023). Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD‐CAM systems: A prospective clinical study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13675
Vancouver
Sanchez-Lara A, Hosney S, Lampraki E, Conejo J, Blatz MB, Barmak AB, et al. Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD‐CAM systems: A prospective clinical study. Journal of Prosthodontics. 2023. doi:10.1111/jopr.13675
BibTeX
@article{SanchezLara2023,
author = {Sanchez-Lara, Alejandro and Hosney, Sherif and Lampraki, Evangelina and Conejo, Julian and Blatz, Markus B and Barmak, Abdul Basir and Ercoli, Carlo and Chochlidakis, Konstantinos},
title = {Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD‐CAM systems: A prospective clinical study},
journal = {Journal of Prosthodontics},
year = {2023},
doi = {10.1111/jopr.13675}
}
EUVIMED