The effect of different denture cleansing solutions on the retention of polyetheretherketone locator attachments
Journal of Prosthodontics · 2023
DOI: 10.1111/jopr.13661 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, 2023. Verfasst von Burcu Bal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Yeditepe University School of Dentistry, Goztepe, Istanbul, Turkey. Hauptthemen laut MEDLINE: Denture Retention, Dental Implants. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Yeditepe University within the scope of Yeditepe University Research Projects and Scientific Activities of Yeditepe University (Istanbul, Turkey).
Abstract (Originalsprache)
Purpose
Prosthetic cleansing solutions have been reported to cause retention loss in implant locator attachments due to the chemical alterations of these attachments. This study aimed to investigate the effects of different denture cleansing solutions on attachments with different retention values. Materials and methods In this study, 160 polyetheretherketone locator attachments were divided into 4 groups according to their attachment retention values (yellow, pink, clear, and violet). Forty attachments from each group were soaked in four different cleansing solutions ( n = 10). The attachments from the four groups were immersed in water, sodium hypochlorite, Corega, and Protefix solutions for a period equivalent to 6 months, according to the manufacturer's recommendations. The locator attachments were then subjected to testing using a universal testing machine. Maximum load to dislodgement according to different solutions was evaluated by one‐way ANOVA test. Statistical significance was set at p < 0.05.
Results
The effect of denture cleansing solutions on the retentive values of attachments was statistically significant ( p < 0.001). Among all cleansing solutions, the highest retention value was found in the violet attachments, and the lowest retention value was found in the yellow attachments. The lowest retention value (0.72 ± 0.05 MPa) was observed when the yellow attachments were immersed in Protefix solution, and the highest retention value (1.96 ± 0.15 MPa) was observed when the violet attachments were immersed in the Corega solution.
Conclusion
For different colored attachments, different cleansing solutions can be suggested to patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Yeditepe University School of Dentistry, Goztepe, Istanbul, Turkey.
ORCID-Profile: Burcu Bal, Zeynep Ozkurt-Kayahan
Förderung
- Yeditepe University within the scope of Yeditepe University Research Projects and Scientific Activities of Yeditepe University (Istanbul, Turkey)
Zitieren
APA
Bal, B., Erkul, S., Erzincanlı, A., Ozkurt-Kayahan, Z., & Kazazoglu, E. (2023). The effect of different denture cleansing solutions on the retention of polyetheretherketone locator attachments. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13661
Vancouver
Bal B, Erkul S, Erzincanlı A, Ozkurt-Kayahan Z, Kazazoglu E. The effect of different denture cleansing solutions on the retention of polyetheretherketone locator attachments. Journal of Prosthodontics. 2023. doi:10.1111/jopr.13661
BibTeX
@article{Bal2023,
author = {Bal, Burcu and Erkul, Selen and Erzincanlı, Ayşe and Ozkurt-Kayahan, Zeynep and Kazazoglu, Ender},
title = {The effect of different denture cleansing solutions on the retention of polyetheretherketone locator attachments},
journal = {Journal of Prosthodontics},
year = {2023},
doi = {10.1111/jopr.13661}
}
EUVIMED