EUVIMEDEUVIMED entdecken
Vergleichsstudie

Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: An in vitro study

Maria Βei, Savvas N Kamalakidis, Argirios L Pissiotis, Konstantinos Michalakis, Olga Naka

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2023.04.019 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Maria Βei und 4 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate student, Department of Prosthodontics, Faculty of Health Sciences, School of Dentistry, Aristotle University, Thessaloniki, Greece. Hauptthemen laut MEDLINE: Denture, Overlay, Ketones, Dental Prosthesis, Implant-Supported, Polyethylene Glycols. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The loss in the retentive capability of implant-supported overdenture attachments has been related to the wear of the retentive inserts. Wear of the abutment coating material when following the replacement period for the retentive inserts requires investigation. PURPOSE: The purpose of this in vitro study was to compare the changes in retentive force of 3 polyamide and a polyetheretherketone denture attachments under repeated insertion and removal cycles in wet conditions while following their manufacturers' replacement time recommendations. MATERIAL AND METHODS: Four different denture attachments (LOCKiT, OT-Equator, Ball attachment, and Novaloc) with their retentive inserts were tested. Four implants were embedded into individual acrylic resin blocks, and 10 abutments for each attachment were used. Forty metal housings with their retentive inserts were attached to polyamide screws with autopolymerizing acrylic resin. A customized universal testing machine was used to simulate insertion and removal cycles. The specimens were mounted on a second universal testing machine at 0, 540, 2700, and 5400 cycles, and the maximum retentive force was recorded. The retentive inserts for LOCKiT (light retention), OT-Equator (soft retention), and Ball attachment (soft retention) were replaced every 540 cycles, while the Novaloc (medium retention) attachments were never replaced. All the abutments were weighed with a precision scale at 0, 2700, and 5400 cycles. The surface of every abutment was examined under a stereomicroscope at ×10 magnification. Data were analyzed with descriptive statistics. Two-way repeated measures ANOVA was used to compare the mean retentive force and mean abutment mass of all groups and time evaluation points. Bonferroni corrections were made to adjust for multiple tests (α=.05). RESULTS: The mean retention loss for LOCKiT was 12.6% after 6 months and 45.0% after 5 years of simulated use. The mean retention loss for OT-Equator was 16.0% after 6 months and 50.1% after 5 years of simulated use. The mean retention loss for Ball attachment was 15.3% after 6 months and 39.1% after 5 years of simulated use. The mean retention loss for Novaloc was 31.0% after 6 months and 59.1% after 5 years of simulated use. The mean abutment mass difference was statistically significant (P .05) for OT-Equator and Novaloc at baseline, 2.5 years, and 5 years. CONCLUSIONS: All tested attachments recorded retention loss under the experimental conditions, even when their manufacturers' recommendations for replacement time for the retentive inserts were followed. Patients should be aware that implant abutments should be replaced after a recommended period since their surfaces also change over time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, OverlayKetonesDental Prosthesis, Implant-SupportedPolyethylene GlycolsNylonsDenture RetentionBenzophenonesPolymersIn Vitro TechniquesHumansMaterials TestingDental Stress AnalysisDental Abutments

Substanzen

KetonespolyetheretherketoneBenzophenonesPolymersPolyethylene GlycolsNylons

Autor:innen und Institutionen

  • Postgraduate student, Department of Prosthodontics, Faculty of Health Sciences, School of Dentistry, Aristotle University, Thessaloniki, Greece.
  • Researcher, Department of Prosthodontics, Faculty of Health Sciences, School of Dentistry, Aristotle University, Thessaloniki, Greece; Adjunct Assistant Professor, Division of Post-graduate Prosthodontics, School of Den…
  • Professor and Director of Postgraduate Prosthodontics, Department of Prosthodontics, Faculty of Health Sciences, School of Dentistry, Aristotle University, Thessaloniki, Greece.
  • Professor and Chair, Department of Restorative Sciences and Biomaterials, Henry M. Goldman School of Dental Medicine, Boston University, Boston, Mass.
  • Assistant Professor, Department of Prosthodontics, Faculty of Health Sciences, School of Dentistry, Aristotle University, Thessaloniki, Greece.

Zitieren

APA

Βei, M., Kamalakidis, S. N., Pissiotis, A. L., Michalakis, K., & Naka, O. (2025). Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2023.04.019

Vancouver

Βei M, Kamalakidis SN, Pissiotis AL, Michalakis K, Naka O. Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: An in vitro study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2023.04.019

BibTeX
@article{ei2025,
  author = {Βei, Maria and Kamalakidis, Savvas N and Pissiotis, Argirios L and Michalakis, Konstantinos and Naka, Olga},
  title = {Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2023.04.019}
}
Kostenlos starten →