EUVIMEDEUVIMED entdecken
Crossref

Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning

Hongseok An iD, Grant J Mickesh, David Cho, John A Sorensen

Journal of Prosthodontics · 2024-01 · 33 (1) · 86-94

DOI: 10.1111/jopr.13658 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 15.02.2023. Verfasst von Hongseok An und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Rehabilitation and Biosciences, Oregon Health & Science University School of Dentistry, Portland, Oregon, USA. Hauptthemen laut MEDLINE: Saliva, Tooth. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Intraoral scanners are used widely as an alternative to conventional impressions, but studies on the influence of finish line location and saliva contamination on scanning trueness are lacking. The purpose of this in vitro study was to evaluate the influence of finish line location and saliva contamination on the scanning trueness of crown finish lines. Materials and methods Three ivorine teeth were prepared for all‐ceramic crowns with finish lines placed equigingivally, 0.5 mm subgingivally, and 1.0 mm subgingivally. A single‐cord technique was used for gingival retraction, and a total of 180 intraoral scans were made using two intraoral scanners (Emerald; Planmeca USA Inc., Hoffman Estates, IL, USA & Trios 3; 3Shape A/S, Copenhagen, Denmark). The prepared teeth were separated from the dentoform and scanned using the same intraoral scanners to create reference scans. All scans were imported to the design software (Dental System 2019; 3Shape A/S, Copenhagen, Denmark). After marking the finish lines of prepared teeth, intraoral scans were aligned to the reference scans for comparisons. Vertical and horizontal marginal discrepancies were measured at four different measuring points (buccal, lingual, mesial, and distal) and analyzed. Two‐way ANOVA and Tukey HSD tests were used for statistical analysis ( α = 0.05).

Results

The average vertical and horizontal discrepancies from various groups ranged from −33 to 440 µm. For both intraoral scanners, subgingival finish line groups showed greater vertical and horizontal discrepancies compared with equigingival finish line groups. Saliva contamination significantly increased both vertical and horizontal discrepancies for all finish line locations. The discrepancy increases due to saliva contamination were greater for the subgingival groups.

Conclusions

Subgingival finish lines were not accurately captured using the intraoral scanners. The presence of saliva significantly reduced scanning trueness, and this was amplified when the finish lines were located subgingivally.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaToothComputer-Aided DesignDental Impression TechniqueCrownsImaging, Three-Dimensional

Stichwörter der Autor:innen

digital impression accuracygingival retractionsaliva contamination

Autor:innen und Institutionen

  • Department of Oral Rehabilitation and Biosciences, Oregon Health & Science University School of Dentistry, Portland, Oregon, USA.
  • Graduate Prosthodontics, Texas A&M University College of Dentistry, Dallas, Texas, USA.
  • New York University College of Dentistry, New York, New York, USA.
  • Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Washington, USA.

ORCID-Profile: Hongseok An

Zitieren

APA

An, H., Mickesh, G. J., Cho, D., & Sorensen, J. A. (2024). Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning. Journal of Prosthodontics, 33(1), 86-94. https://doi.org/10.1111/jopr.13658

Vancouver

An H, Mickesh GJ, Cho D, Sorensen JA. Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning. Journal of Prosthodontics. 2024;33(1):86-94. doi:10.1111/jopr.13658

BibTeX
@article{An2024,
  author = {An, Hongseok and Mickesh, Grant J and Cho, David and Sorensen, John A},
  title = {Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning},
  journal = {Journal of Prosthodontics},
  year = {2024},
  volume = {33},
  number = {1},
  pages = {86--94},
  doi = {10.1111/jopr.13658}
}
Kostenlos starten →