Effect of intraoral scanning distance on the marginal discrepancy of milled interim crowns
Journal of Prosthodontics · 2024
DOI: 10.1111/jopr.13646 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Yunus Emre Ozden und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Yeditepe University Faculty of Dentistry, Istanbul, Turkey. Hauptthemen laut MEDLINE: Computer-Aided Design, Tooth. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Purpose
To compare the marginal discrepancy between milled interim crowns fabricated using intraoral digital scans acquired at different scanning distances. Materials and methods Ten acrylic typodont teeth were prepared for interim crowns. Three different resin frames of 2.5‐, 5‐, and 7.5‐mm heights were fabricated and attached to an intraoral scanner (Omnicam). Three groups were created based on the different scanning distances tested: 2.5 mm (Group A), 5 mm (Group B), and 7.5 mm (Group C). Intraoral digital scans were performed on four tooth surfaces: mesial, distal, buccal, and lingual ( n = 10). Each experimental scan was used to design and fabricate a milled polymethylmethacrylate anatomically contoured crown. Vinyl polyether silicone was used three times to assess the marginal discrepancy of the specimens by measuring five marginal points on digital photographs. One‐way analysis of variance test was used to analyze the data, followed by Tukey's honestly significant difference test ( α = 0.05).
Results
The mean marginal discrepancy values in Group C were significantly higher than those in Groups A ( p ≤ 0.000) and B ( p = 0.001). There was no significant difference between Groups A and B ( p = 0.702). There were no significant differences among the four surfaces in any of the scanning distance groups ( p 1 = 0.583, p 2 = 0.390, and p 3 = 0.135; p > 0.05).
Conclusions
The interim crowns fabricated with a scanning distance of 7.5 mm showed the greatest marginal discrepancy when compared with crowns fabricated using 2.5‐ and 5‐mm scanning distances.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Yeditepe University Faculty of Dentistry, Istanbul, Turkey.
ORCID-Profile: Zeynep Ozkurt-Kayahan
Zitieren
APA
Ozden, Y. E., Ozkurt-Kayahan, Z., & Kazazoglu, E. (2024). Effect of intraoral scanning distance on the marginal discrepancy of milled interim crowns. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13646
Vancouver
Ozden YE, Ozkurt-Kayahan Z, Kazazoglu E. Effect of intraoral scanning distance on the marginal discrepancy of milled interim crowns. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13646
BibTeX
@article{Ozden2024,
author = {Ozden, Yunus Emre and Ozkurt-Kayahan, Zeynep and Kazazoglu, Ender},
title = {Effect of intraoral scanning distance on the marginal discrepancy of milled interim crowns},
journal = {Journal of Prosthodontics},
year = {2024},
doi = {10.1111/jopr.13646}
}
EUVIMED