EUVIMEDEUVIMED entdecken
Vergleichsstudie

Can Recordings of Tongue Motor‐Evoked Potentials Be Improved? Comparison of Two Electrode Types and Their Reliability

William Poncin iD, Simple Futarmal Kothari, Jin Magara, Makoto Inoue, Eduardo Castrillon, Mohit Kothari

Journal of Oral Rehabilitation · 2026

DOI: 10.1111/joor.70098 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Oral Rehabilitation, 2026. Verfasst von William Poncin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pole of Pulmonology, ENT and Dermatology (LUNS), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCLouvain)…. Hauptthemen laut MEDLINE: Evoked Potentials, Motor, Tongue, Transcranial Magnetic Stimulation, Motor Cortex. Die Arbeit nennt 42 Literaturangaben. Gefördert von: European Respiratory Society (ERS) Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In transcranial magnetic studies (TMS), motor‐evoked potentials (MEPs) recorded from the tongue provide important insights into corticobulbar excitability and neuromuscular control. However, their clinical and research utility remains limited due to anatomical and technical challenges, particularly those affecting electrode stability and signal quality.

Objective

This study aimed to compare TMS‐derived outcomes obtained with traditional surface electrodes and novel suction‐based electrodes.

Methods

Nineteen healthy adults participated in a repeated‐measures, cross‐over design. On Day 1, each participant completed two test sessions per electrode type (intra‐session reliability). Thirteen participants returned for a third test session at least 1 week later (inter‐session reliability). Resting motor threshold (rMT) was determined. MEP amplitude (MEP_Amp) and latency (MEP_Lat) were assessed at five single‐pulse stimulation intensities (90%, 100%, 120%, 140% and 160% of rMT). Reliability was analyzed using intraclass correlation coefficients (ICCs, using lower 95% CI bound to gauge reliability strength).

Results

Suction electrodes yielded significantly lower rMT and higher MEP_Amp at 120%–160% rMT. For both electrode types, intra‐session reliability for rMT was excellent (ICCs > 0.90) and poor to moderate for MEP_Amp and MEP_Lat (ICCs < 0.75). Inter‐session reliability was poor (ICCs < 0.50) across all outcomes for both electrode types.

Conclusion

Compared to surface electrodes, suction electrodes improved signal quality as indicated by lower rMT and higher MEP_Amp. However, both electrode types exhibited substantial intra‐ and inter‐session variability. Although suction electrodes enhance TMS signal quality, the poor test–retest reliability of tongue MEPs currently limits their utility as biomarkers. Methodological refinements are needed to further improve reliability in TMS‐based tongue assessments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Evoked Potentials, MotorTongueTranscranial Magnetic StimulationMotor CortexHumansMaleFemaleReproducibility of ResultsAdultElectrodesCross-Over StudiesHealthy VolunteersElectromyographyYoung Adult

Stichwörter der Autor:innen

cortical plasticityelectrodemotor‐evoked potentialsreliabilitytonguetranscranial magnetic stimulation

Autor:innen und Institutionen

  • Pole of Pulmonology, ENT and Dermatology (LUNS), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCLouvain), Brussels, Belgium.
  • Department of Clinical Medicine, Hammel Neurorehabilitation Centre and University Research Clinic, Aarhus University, Hammel, Denmark.
  • Department of Clinical Neurophysiology, Aarhus University Hospital & Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Unit of Dysphagia Rehabilitation, Niigata University Medical & Dental Hospital, Niigata, Japan.
  • Division of Dysphagia Rehabilitation, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
  • Section for Orofacial Pain and Jaw Function, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark.

ORCID-Profile: William Poncin

Förderung

  • European Respiratory Society (ERS) Fellowship

Zitieren

APA

Poncin, W., Kothari, S. F., Magara, J., Inoue, M., Castrillon, E., & Kothari, M. (2026). Can Recordings of Tongue Motor‐Evoked Potentials Be Improved? Comparison of Two Electrode Types and Their Reliability. Journal of Oral Rehabilitation. https://doi.org/10.1111/joor.70098

Vancouver

Poncin W, Kothari SF, Magara J, Inoue M, Castrillon E, Kothari M. Can Recordings of Tongue Motor‐Evoked Potentials Be Improved? Comparison of Two Electrode Types and Their Reliability. Journal of Oral Rehabilitation. 2026. doi:10.1111/joor.70098

BibTeX
@article{Poncin2026,
  author = {Poncin, William and Kothari, Simple Futarmal and Magara, Jin and Inoue, Makoto and Castrillon, Eduardo and Kothari, Mohit},
  title = {Can Recordings of Tongue Motor‐Evoked Potentials Be Improved? Comparison of Two Electrode Types and Their Reliability},
  journal = {Journal of Oral Rehabilitation},
  year = {2026},
  doi = {10.1111/joor.70098}
}
Kostenlos starten →