EUVIMEDEUVIMED entdecken
Crossref

Reliability of transcranial magnetic stimulation-evoked responses on knee extensor muscles during cycling

Jenny Zhang, Zachary J McClean, Neda Khaledi, Sophie-Jayne Morgan, Guillaume Y Millet, Saied Jalal Aboodarda

Experimental Brain Research · 2024

DOI: 10.1007/s00221-024-06859-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experimental Brain Research, 2024. Verfasst von Jenny Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, KNB 420, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Evoked Potentials, Motor, Bicycling, Electromyography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 73 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcranial magnetic stimulation (TMS) measures the excitability and inhibition of corticomotor networks. Despite its task-specificity, few studies have used TMS during dynamic movements and the reliability of TMS paired pulses has not been assessed during cycling. This study aimed to evaluate the reliability of motor evoked potentials (MEP) and short- and long-interval intracortical inhibition (SICI and LICI) on vastus lateralis and rectus femoris muscle activity during a fatiguing single-leg cycling task. Nine healthy adults (2 female) performed two identical sessions of counterweighted single-leg cycling at 60% peak power output until failure. Five single pulses and ten paired pulses were delivered to the motor cortex, and two maximal femoral nerve stimulations (Mmax) were administered during two baseline cycling bouts (unfatigued) and every 5 min throughout cycling (fatigued). When comparing both baseline bouts within the same session, MEP·Mmax-1 and LICI (both ICC: >0.9) were rated excellent while SICI was rated good (ICC: 0.7-0.9). At baseline, between sessions, in the vastus lateralis, Mmax (ICC: >0.9) and MEP·Mmax-1 (ICC: 0.7) demonstrated good reliability; LICI was moderate (ICC: 0.5), and SICI was poor (ICC: 0.3). Across the fatiguing task, Mmax demonstrated excellent reliability (ICC > 0.8), MEP·Mmax-1 ranged good to excellent (ICC: 0.7-0.9), LICI was moderate to excellent (ICC: 0.5-0.9), and SICI remained poorly reliable (ICC: 0.3-0.6). These results corroborate the cruciality of retaining mode-specific testing measurements and suggest that during cycling, Mmax, MEP·Mmax-1, and LICI measures are reliable whereas SICI, although less reliable across days, can be reliable within the same session.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcranial Magnetic StimulationEvoked Potentials, MotorBicyclingElectromyographyMuscle, SkeletalHumansMaleFemaleAdultReproducibility of ResultsYoung AdultMotor CortexKneeMuscle Fatigue

Stichwörter der Autor:innen

Corticospinal excitabilityIntracortical inhibitionRectus femorisRepeatabilityVastus Lateralis

Autor:innen und Institutionen

  • Faculty of Kinesiology, University of Calgary, KNB 420, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
  • Faculty of Physical Education and Sport Sciences, Kharazmi University, Tehran, Iran.
  • Inter-university Laboratory of Human Movement Biology, Université Jean Monnet Saint-Etienne, Université Savoie Mont-Blanc, Lyon 1, Saint-Etienne, F-42023, France.
  • Faculty of Kinesiology, University of Calgary, KNB 420, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. saiedjalal.aboodarda@ucalgary.ca.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Zhang, J., McClean, Z. J., Khaledi, N., Morgan, S. J., Millet, G. Y., & Aboodarda, S. J. (2024). Reliability of transcranial magnetic stimulation-evoked responses on knee extensor muscles during cycling. Experimental Brain Research. https://doi.org/10.1007/s00221-024-06859-y

Vancouver

Zhang J, McClean ZJ, Khaledi N, Morgan SJ, Millet GY, Aboodarda SJ. Reliability of transcranial magnetic stimulation-evoked responses on knee extensor muscles during cycling. Experimental Brain Research. 2024. doi:10.1007/s00221-024-06859-y

BibTeX
@article{Zhang2024,
  author = {Zhang, Jenny and McClean, Zachary J and Khaledi, Neda and Morgan, Sophie-Jayne and Millet, Guillaume Y and Aboodarda, Saied Jalal},
  title = {Reliability of transcranial magnetic stimulation-evoked responses on knee extensor muscles during cycling},
  journal = {Experimental Brain Research},
  year = {2024},
  doi = {10.1007/s00221-024-06859-y}
}
Kostenlos starten →