EUVIMEDEUVIMED entdecken
Crossref

In vivo evaluation of T‐Scan in quantifying occlusal contact

Qing Wang iD, Zhe Zhao, Jiale Li, Ruifeng Zhao, Ming Zhou, Kai Tang, Shizhu Bai, Chufan Ma, Fu Wang

Journal of Oral Rehabilitation · 2024

DOI: 10.1111/joor.13732 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Oral Rehabilitation, 2024. Verfasst von Qing Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Labora…. Hauptthemen laut MEDLINE: Dental Occlusion. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: the National Natural Science Foundation of China, the National Clinical Research Centre for Oral Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The T‐scan system has been used previously to analyse occlusion, but the quantitative analysis of occlusal contact by T‐Scan system has yet to be reported.

Objectives

To evaluate the reliability and validity of T‐Scan system for quantitatively measuring occlusal contact area and occlusal contact number.

Methods

Twenty‐two individuals with normal occlusion, 11 men and 11 women, were recruited for the study. Two occlusal analysis methods, including silicone transmission analysis method (STA) and T‐Scan occlusion analysis method (TSO), were used to make quantitative analysis to measure occlusal contact area (OCA) and occlusal contact number (OCN). A test–retest check was performed with an interval of 2 weeks. The values of intraclass correlation coefficients (ICC) between test‐retest of each method were calculated for reliability evaluation. Pearson correlations analysis, paired t ‐tests, regression analysis and Bland–Altman analysis were performed for validity evaluation.

Results

The ICC values of STA were greater than those of TSO for OCA while for OCN, ICC values of TSO were greater than STA. The higher OCA and OCN values were found in TSO compared with STA. Pearson's correlation coefficient indicated strong relations between TSO and STA (0.730–0.812) for OCA, while good relations between then (0.569–0.583) for OCN. Paired t ‐test showed a significant difference between the OCA and OCN values between TSO and STA. Bland–Altman analysis showed good agreement between OCA and OCN values of TSO and STA both in men and women. Regression analysis identified a linear correlation between OCA values obtained from these two methods.

Conclusions

T‐Scan method showed strong reliability for measuring OCA and OCN quantitatively. Strong correlations were found between OCA values from TSO and STA method, but the validity of TSO for measuring OCN needs to be promoted. Clinical Significance T‐Scan system demonstrates good potential in quantitative analysis of occlusion, which will expand its clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental OcclusionHumansFemaleMaleReproducibility of ResultsAdultYoung AdultJaw Relation Record

Stichwörter der Autor:innen

T‐Scan occlusal analysis methodocclusal contact areaocclusal contact numberreliabilitysilicone transmission analysis methodvalidity

Autor:innen und Institutionen

  • State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatolo…
  • Department of Prosthodontics, Inner Mongolia Autonomous Region People's Hospital, Hohhot, Inner Mongolia, PR China.
  • State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Digital Dentistry Center, School of Stomatology,…
  • Department of Stomatology, Air Force Medical Center, The Fourth Military Medical University, Xi'an, PR China.

ORCID-Profile: Qing Wang

Förderung

  • the National Natural Science Foundation of China
  • the National Clinical Research Centre for Oral Diseases

Zitieren

APA

Wang, Q., Zhao, Z., Li, J., Zhao, R., Zhou, M., Tang, K., Bai, S., Ma, C., & Wang, F. (2024). In vivo evaluation of T‐Scan in quantifying occlusal contact. Journal of Oral Rehabilitation. https://doi.org/10.1111/joor.13732

Vancouver

Wang Q, Zhao Z, Li J, Zhao R, Zhou M, Tang K, et al. In vivo evaluation of T‐Scan in quantifying occlusal contact. Journal of Oral Rehabilitation. 2024. doi:10.1111/joor.13732

BibTeX
@article{Wang2024,
  author = {Wang, Qing and Zhao, Zhe and Li, Jiale and Zhao, Ruifeng and Zhou, Ming and Tang, Kai and Bai, Shizhu and Ma, Chufan and Wang, Fu},
  title = {In vivo evaluation of T‐Scan in quantifying occlusal contact},
  journal = {Journal of Oral Rehabilitation},
  year = {2024},
  doi = {10.1111/joor.13732}
}
Kostenlos starten →